beautypg.com

Cisco ONS 15454 SDH User Manual

Page 4

background image

15-4

Cisco ONS 15454 SDH Reference Manual, R4.6

April 2008

Chapter 15 Performance Monitoring

15.4.1 E1-N-14 Card and E1-42 Card Performance Monitoring Parameters

Figure 15-1 Monitored Signal Types for the E1-N-14 Card and E1-42 Card

Figure 15-2

shows where overhead bytes detected on the application-specific integrated circuits (ASICs)

produce performance monitoring parameters for the E1-N-14 card.

Note

The E1-42 card uses the same PM read points. The only difference from the

Figure 15-2

is that the

number of ports on the E1-42 equal 42.

Figure 15-2 PM Read Points on the E1-N-14 Card

The PM parameters for the E1-N-14 card and E1-42 card are described in

Table 15-2 on page 15-5

through

Table 15-4 on page 15-6

.

71101

ONS 15454

SDH

E1

STM16

Fiber

Near End

E1 Signal

CRC4 Framing Path PMs Near + Far End Supported

ONS 15454
SDH

E1

STM16

Far End

E1 Signal

VC-12 Low-Order Path PMs Near End Supported

71100

ONS 15454 SDH

E1 Card

LIU

Framer

BTC

Tx/Rx

Cross-Connect

Card

STM-N

CV-L
ES-L
SES-L

Rx P-EB
Rx P-BBE
Rx P-ES
Rx P-SES
Rx P-UAS
Rx P-ESR
Rx P-SESR
Rx P-BBER

Tx P-EB
Tx P-BBE
Tx P-ES
Tx P-SES
Tx P-UAS
Tx P-ESR
Tx P-SESR
Tx P-BBER

E1 Side

Low-
Order
Path
Level

SDH Side

LP-EB
LP-BBE
LP-ES
LP-SES
LP-UAS
LP-ESR
LP-SESR
LP-BBER

PMs read on Framer

PMs read on LIU