15-34

Cisco ONS 15454 SDH Reference Manual, R4.6

April 2008

Chapter 15 Performance Monitoring

15.6.3 STM-4 and STM4 SH 1310-4 Card Performance Monitoring Parameters

MS-PSC-W

For a working line in a two-fiber MS-SPRing, Multiplex Section
Protection Switching Count-Working (MS-PSC-W) is a count of the
number of times traffic switches away from the working capacity in the
failed line and back to the working capacity after the failure is cleared.
PSC-W increments on the failed working line and PSC increments on the
active protect line.

MS-PSD-W

For a working line in a two-fiber MS-SPRing, Multiplex Section
Protection Switching Duration-Working (MS-PSD-W) is a count of the
number of seconds that service was carried on the protection line.
MS-PSD-W increments on the failed working line and PSD increments on
the active protect line.

1.

4-fiber MS-SPRing is not supported on the STM-4 and STM4 SH 1310-4 cards; therefore, the MS-PSC-S and MS-PSC-R PM
parameters do not increment.

Table 15-38 High-Order VC4 and VC4-Xc Path PM Parameters for the Near-End STM-4

and STM4 SH 1310-4 Cards

Parameter

Definition

Note

SDH path PM parameters do not increment unless IPPM is enabled. See the

“15.2 Intermediate-Path Performance Monitoring” section on page 15-2

. The far-end IPPM

feature is not supported on the STM-4 and STM4 SH 1310-4 cards. However, SDH path PM
parameters can be monitored by logging into the far-end node directly.

HP-EB

High-Order Path Errored Block (HP-EB) indicates that one or more bits
are in error within a block.

HP-ES

High-Order Path Errored Second (HP-ES) is a one-second period with one
or more errored blocks or at least one defect.

HP-SES

High-Order Path Severely Errored Seconds (HP-SES) is a one-second
period containing 30 percent or more errored blocks or at least one defect.
SES is a subset of ES.

HP-UAS

High-Order Path Unavailable Seconds (HP-UAS) is a count of the seconds
when the VC path was unavailable. A low-order path becomes unavailable
when ten consecutive seconds occur that qualify as HP-SESs, and it
continues to be unavailable until ten consecutive seconds occur that do not
qualify as HP-SESs.

HP-BBE

High-Order Path Background Block Error (HP-BBE) is an errored block
not occurring as part of an SES.

HP-ESR

High-Order Path Errored Second Ratio (HP-ESR) is the ratio of errored
seconds to total seconds in available time during a fixed measurement
interval.

Table 15-37 Protection Switch Count PM Parameters for the Near-End STM-4 and STM4 SH 1310-4

Cards (continued)

Parameter

Definition