3 e-series ethernet history window – Cisco ONS 15454 SDH User Manual
Page 16
15-16
Cisco ONS 15454 SDH Reference Manual, R4.6
April 2008
Chapter 15 Performance Monitoring
15.5.2 G-Series Ethernet Card Performance Monitoring Parameters
Note
Line utilization numbers express the average of ingress and egress traffic as a percentage of capacity.
Note
The E-Series Ethernet card is a Layer 2 device or switch and supports Trunk Utilization statistics. The
Trunk Utilization statistics are similar to the Line Utilization statistics, but shows the percentage of
circuit bandwidth used rather than the percentage of line bandwidth used. The Trunk Utilization statistics
are accessed via the card view Maintenance tab.
15.5.1.3 E-Series Ethernet History Window
The Ethernet History window lists past Ethernet statistics for the previous time intervals. Depending on
the selected time interval, the History window displays the statistics for each port for the number of
previous time intervals as shown in
. The listed parameters are defined in
15.5.2 G-Series Ethernet Card Performance Monitoring Parameters
CTC provides Ethernet performance information, including line-level parameters, port bandwidth
consumption, and historical Ethernet statistics. The G-Series Ethernet performance information is
divided into the Statistics, Utilization, and History tabbed windows within the card view Performance
tab window. The following sections describe PM parameters provided for the G1000-4 and G1K-4
Ethernet cards.
Table 15-16 MaxBaseRate for STS Circuits
STS
maxBaseRate
STS-1
51840000
STS-3c
155000000
STS-6c
311000000
STS-12c
622000000
Table 15-17 Ethernet History Statistics per Time Interval
Time Interval
Number of Intervals Displayed
1 minute
60 previous time intervals
15 minutes
32 previous time intervals
1 hour
24 previous time intervals
1 day (24 hours)
7 previous time intervals