Specifications dimensions, Ordering information, Ge interlogix – Interlogix 5600 Series User Manual
Page 4
![background image](/manuals/679378/4/background.png)
Voltage ..................................................................... 9 – 16V DC
Current .............................................. 12mA typical, 20mA max.
Relay Output: Normal ......................................... <15 W (closed)
Alarm ............................................................ >1 MW (open)
Open 4 seconds upon alarm
Maximum loop rating .................................. 16V DC, 50mA
Wire Terminals ........................................................ 22-18 AWG
Operating Temperature ............... 0° to +120°F (–18° to +50°C)
Humidity ........................................ 10% to 90% noncondensing
Lightning Suppression ..................... 400 Watts for 1msec pulse
RF Immunity ......................................... 20 V/m, 1 to 1000 MHz
Glass Types
Plate ...................................... 3/32'' (2.4mm) to 3/8" (9mm)
Tempered ............................. 1/8'' (3.2mm) to 1/4" (6.4mm)
Laminated ............................ 1/8'' (3.2mm) to 1/4" (6.4mm)
Wired .............................................................. 1/4" (6.4mm)
Mounting Location ............................................................ Frame
Range of glass surface covered (radius from sensor)
Single-pane window ..................................... up to 10' (3m)
Multi-pane window ...................................... up to 8' (2.4m)
Sliding-glass door ........................................ up to 8' (2.4m)
Armor coated glass ...................................... up to 8' (2.4m)
Minimum Glass Size .................... 12" (305mm) x 12" (305mm)
Note: Mounting sensor or magnet on steel surface will
reduce gap.
Magnet Gap Distance ............................. 3/4" (19mm) maximum
Housing Material ..................................... Flame Retardant ABS
Color ............................................................ White or Mahogany
Specifications
Dimensions
www.GE-Interlogix.com
© 2003 GE INTERLOGIX
12345 SW Leveton Drive
Tualatin, OR 97062
Phone: 503-692-4052
USA & Canada: 800-547-2556
Technical Service: 800-648-7424
FaxBack: 800-483-2495
GE Interlogix
FCC
This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1)
This device may not cause harmful interference, and (2)
this device must accept any interference received, including
interference that may cause undesired operation.
Ordering Information
Description
Model Number
Color Choices
ShatterPoint™
5600-W
White
ShatterPoint™, with Form C relay and tamper switch
5605-W
White
ShatterPoint™, with magnetic contact
5620-W
White
ShatterPoint™, with Form C relay, tamper switch and magnetic contact
5625-W/M
White or Mahogany
Hand-held Tester
5709C-W
White
Replacement magnet
1838-N/M
Cloud White or Mahogany
Sensor
Magnet
3.95"
(100mm)
1.25"
(32mm)
0.9"
(23mm)
1.5"
(38mm)
0.25"
(6mm)
0.38"
(10mm)
14329 Rev B 05/03