Location 206 - auto disarm day selection – Interlogix NX-8V2 REV H Installation Manual User Manual
Page 56

Chapter 2: Reporting codes
52
NX-8V2 Control Panel Installation Manual
Location
Zone
type
Description
Default
152
22
Alarm code
20
153
22
Feature selection
24, 15, 78, 0, 0
154
23
Alarm code
21
155
23
Feature selection
24, 15, 78, 0, 0
156
24
Alarm code
22
157
24
Feature selection
1, 13, 378, 0, 0
158
25
Alarm code
14
159
25
Feature selection
248, 45, 0, 0, 0
160
26
Alarm code
5
161
26
Feature selection
467, 125, 5678, 0, 0
162
27
Alarm code
5
163
27
Feature selection
457, 1257, 5678, 0, 0
164
28
Alarm code
7
165
28
Feature selection
6, 12457, 5678, 0, 0
166
29
Alarm code
5
167
29
Feature selection
457, 125, 5678, 1, 0
168
30
Alarm code
7
169
30
Feature selection
5, 1245, 5678, 1, 0
Locations 170 to 205 - Reserved
Location 206 - Auto disarm day selection
Location 206 has one segment of feature selection data. Use this location to
program which days the system autodisarms. If a zone is faulted when the panel
tries to autodisarm, the zone is bypassed.
1 = Sunday
2 = Monday
3 = Tuesday
4 = Wednesday
5 = Thursday
6 = Friday
7 = Saturday
8 = Reserved