Chapter 2: Reporting codes
32
NX-8V2 Control Panel Installation Manual
Zone type
Description
24. Manual fire
Illuminates the Fire LED and sounds the temporal siren each time the
zone is shorted. it also flashes (rapidly) the Fire LED, indicating a
problem if the zone is open.
25. Chime only
This zone creates no alarm regardless of the armed state of the
control panel. It chimes anytime it is faulted and displays on the
keypad. Local only.
26. Interior follower delay
2
Instant when the system is armed and no entry or exit delay is being
timed. It is delayed 2 times during entry and exit. It automatically
bypasses if enabled in Segment 1 of Location 23.
27. Interior follower force
armable
Instant when the system is armed and no entry or exit delay is being
timed. It is delay 1 time during entry and exit. It automatically
bypasses if enabled in Segment 1 of Location 23.
28. Entry/exit force
armable delay 2
A trip starts entry delay 2. The lack of a trip during exit delay enables
the automatic bypass or instant mode if programmed.
29. Interior follower with
activity supervision
Instant when the system is armed and no entry or exit delay is being
timed. It is delayed during entry and exit delay times. It sends a report
if the zone activity time is reached without a change of state (refer to
Segment 11 of Location 40). It automatically bypasses if enabled in
Segment 1 of Location 23.
30. Entry/exit with activity
supervision
A trip starts entry delay 1. It sends a report if the zone activity time is
reached without a change of state (refer to Segment 11 of Location
40). The lack of a trip during exit delay enables the automatic bypass
or instant mode if programmed.
A zone may reside in any combination of the eight partitions. If a burglary zone
resides in more than one partition, it will only be active when all partitions it
resides in are armed. A zone that resides in more than one partition will be
reported to its lowest partition number.
Location 25
Zones 1 to 8 zone type
Location 25 has eight segments of numerical data. Use this location to
program the zone type for zones 1 to 8. Use segment 1 for zone 1,
segment 2 for zone 2, etc. The segment defaults are 3, 5, 6, 6, 6, 6, 6,
6.
Location 26
Zones 1 to 8 partition
Location 26 has eight segments of feature selection data. Use this
location to select the partitions (1 to 8) that zones 1 to 8 reside in.
Each segment corresponds to a zone (segment 1 to zone 1, segment
2 to zone 2, etc.). In each segment, enter 1 for partition 1 through 8 for
partition 8.
Location 27
Zones 9 to 16 zone types
Location 27 has eight segments of numerical data. Use this location to
program the zone type for zones 9 to 16. Use segment 1 for zone 9,
segment 2 for zone 10, etc. The segment defaults are 6, 6, 6, 6, 6, 6,
6, 6.