Minimum system configurations for ul installations – Interlogix NX-8V2 REV B Installation Manual User Manual
Page 8

protected area, is acceptable, provided it is rated for outside
service and alarm conditions are transmitted to:
a) The dispatch location of the law enforcement agency having
jurisdiction over the protected property or
b) A central station or residential monitoring station complying
with the Standard for Central-Station Alarm Services, UL 827.
In a mercantile burglar alarm system, an alarm sounding
device located within the area of greatest protection, or outside
the area of greatest protection but within an area protected by
an alarm system and that shares a common control unit with
the system installed in the area of greatest protection, is
acceptable provided it is rated for inside service and alarm
conditions are transmitted to:
a) The dispatch location of the law enforcement agency having
jurisdiction over the protected property or
b) A central station or residential monitoring station complying
with the Standard for Central-Station Alarm Services, UL 827.
An inside sounding device shall be mounted at least 10 feet
(3.05 m) above the floor or at the surface of the ceiling. When
there is fixed construction within the area that could provide
access for an intruder, the alarm sounding device shall also be
mounted at least 4 feet (1.2 m), as measured horizontally away
from the edges of the fixed construction or at least 10 feet
(3.05 m) above it so as to minimize access by an intruder.
Table 6: Use markings
Model number
Use marking
Subassemblies
NX-8 (*S)
Res Fire1 and Burg2, Com Burg4, Acc5,
Homehealth Care Control Unit
Motherboard
NX-8E (*S)
Res Fire1 and Burg2, Com Burg4, Acc5,
Homehealth Care Control Unit
Motherboard
NX-8V2 (*S)
Res Fire1 and Burg2, Com Burg4, Acc5,
Homehealth Care Control Unit
Motherboard
NX-508, NX-508E
Res Fire1 and Burg2, Com Burg4, Acc5
Output
NX-507
Res Fire1 and Burg2, Com Burg4, Acc5
Relay Output Module
NX-216, NX-216E
Res Fire1 and Burg2, Com Burg4, Acc5
Zone Expander
Accessories
Model number
Use marking
NX-148, NX-148E (*S),
NX-124, NX-124E (*S),
NX-116, NX-108, NX-
108E (*S), NX-1208E
(*S), NX-1248E (*S), NX-
1308, NX-1308E, NX-
1316, NX-1316E, NX-
1324, NX-1324E (*S),
NX1348E (*S), NX-
1508E, NX-1516E (*S),
NX1616E, NX-1648E
Res Fire1 and Burg2, Com Burg4, Acc5 ,
and Homehealth Care Keypad
NX-148E-RF (*S)
Res Fire1 and Burg2, Acc5 , and
Homehealth Care Keypad
NX-003
Res Fire1 and Burg2, Acc5 Enclosure
1 Res Fire = Residential Fire
2 Res Burg = Residential Burglar
3 Com Fire = Commercial Fire
4 Com Burg = Commercial Burglar
5 Acc = Access Control
Table 7: System markings (+)
Model number Signaling
means
Other
NX-8 (*S), NX-
8V2 (*S)
DACT
Central Station, Local Mercantile
and Police Station Connected
NX-8E (*S)
DACT
Central Station, Local Mercantile
and Police Station Connected,
Proprietary
WARNING:
Electrical codes will vary, depending upon the
country and city where the system is installed. It is the
installer’s responsibility to ensure that the electrical installation
is safe and conforms to all applicable codes, laws, or
regulations. Only qualified persons should connect this device
to the main supply..
Minimum system configurations for UL installations
The following requirements apply to residential fire, residential
burglary, and commercial burglary installations.
•
The NetworX NX-8V2 panel is necessary to initiate
residential and commercial installations.
•
At least one compatible keypad is needed for all
applications.
•
The AD10-12 bell and UL Approved bell-housing shall be
used for all applications.
•
Commercial UL applications require the NX-003-C metal
enclosure. Supplied screws to be used.
•
A minimum of two keypads is required for home health
applications, and each keypad must be set to a unique
address.
•
The wireless devices are only UL listed for residential
applications.
8
NX-8V2 Control Panel Installation Instructions