NX-4V2 Control Panel Installation Instructions
9
e
electable 50 mS or 500 mS
Loop respons
S
Operating temperature
to 49°C)
32 to 120°F (0
LED keypad
Current draw
/o
30 mA max.
in. (16.3 x 10.2 x 2.8 cm)
Zones normal w
sounder
Dimensions
1
55 mA
6.4 x 4.0 x 1.1
NX148E LCD keypad
er
x 1.0 in. (16.3 x 13.5 x 2.5 cm)
Current draw
Without sound
Dimensions
110 mA max.
75 mA
6.4 x 5.3
Metal enclosure
dimension
x 3.50 in. (28.58 x 28.58 x 8.90
cm)
11.25 x 11.25
Shipping weight
9 lb. (4.1 kg)
Regulatory information
FCC compliance
This device complies with part 15 of the FCC
rules. Operation is subject to the following
conditions:
This device may not cause harmful interference.
This device must accept any interference
received, including interference that may cause
undesired operation.
Changes or modifications not expressly approved
by the party responsible for compliance could
void the user’s authority to operate the
equipment.
Complies with Part 68 FCC Rules.
ACTA (FCC) ID: GCQUSA-33408-AL-E
IC: 1175A-NXV2
Contact information
For contact information, see www.utcfireandsecurity.com or
www.interlogix.com.
For technical support, toll-free: 888.437.3287 in the US
including Alaska, Hawaii, Puerto Rico, and Canada. Outside
the tool-free area, contact your dealer.
Copyright © 2011 UTC Fire & Security. All rights reserved.
ANSI/SIA CP-01 requirements
CP-01 feature descriptions and specifications are listed in Table 7 below. The following are requirements for compliance with
ANSI/SIA CP-01 standards.
Note: Where a conflict exists, UL requirements take precedence over ANSI/SIA requirements.
•
Minimum system requirements:
•
•
One control panel
• • Two
keypads
•
Do not enable remote arming in SIA classified installations.
•
Off premise transmission must be in the SIA format.
•
Do not exceed 1 minute for the abort window and entry delay.
Note: A call-waiting cancel on a noncall-waiting line prevents successful connection to the central station.
Table 7: CP-01 feature descriptions and specifications
CP-O1 feature description
Feature description as shown in
manual
Program
location
Seg/opt Default
CP-01required
setting
Exit 1 delay
24
2
60
45 to 240 seconds
Exit time
Exit 2 delay
24
4
60
45 to 240 seconds
Progress annunciation /
disable - for silent exit
Silent keypad option
93
a
2
All annunciators enabled Allowed (individual
keypads may be disabled)
Exit time restart (reexit)
This feature is not programmable in the panel.
Enabled
Auto stay arm on unvacated
premises
Auto bypass
23
1/3
Enabled
Enabled