A-7

EPIM-A and EPIM-X (AUI Port)

EPIM-A and EPIM-X (AUI Port)

The EPIM-A is a DB-15 female connector used to attach segments to an external
transceiver. The EPIM-X is equipped with dual internal transceivers. It has a
DB-15 male connector used to attach segments to an AUI cable. Figure A-6 shows
both modules.

Figure A-6. The EPIM-A and EPIM-X

Table A-4 lists the DB-15 pinouts.

*

Connector Shell:

Protective Ground

Table A-4. DB-15 Pinouts

Pin Number

Represents

Pin Number

Represents

1

Logic Ref.

10

Transmit -

2

Collision +

11

Logic Ref.

3

Transmit

12

Receive -

4

Logic Ref.

13

Power (+12Vdc)

5

Receive

14

Logic Ref.

6

Power Return

15

No Connection

7

No Connection

*

Connector Shell

Positive Ground

9

Collision -