beautypg.com

The power screen, The power supply specific screen – Cabletron Systems Environmental Module TM 9C300-1 User Manual

Page 27

background image

3-15

Interactive Mode

The Power Screen

Select from the System Screen, as shown in Figure 3-15, to access
information about the chassis power supply configuration.

Line 1 of the Power Screen, as shown in Figure 3-16, displays the number of
power supplies currently configured and the availability of power redundancy.

Lines 2 and 3 display the power supply status as either ON, OFF DUE TO
MANAGEMENT, or FAULT.

Line 4 is used to access information about a specific power supply module by
selecting a power supply number.

Figure 3-16. The Power Screen

Select to return to the System Screen.

The Power Supply Specific Screen

Select a power supply number from line 4 of the Power Screen, as shown in
Figure 3-16, to learn about a specific power supply in the MMAC-Plus chassis.
There is an LCD screen available for each installed power supply, as shown in
Figure 3-17.

Line 1 identifies the power supply selected and its serial number.

Line 2 identifies the power supply’s hardware revision, firmware revision of the
diagnostic controller and power loading factor as a percentage of its capacity.

Line 3 provides the input and output voltages of the power supply.

Figure 3-17. The Power Supply Specific Screen

Select to return to the Power Screen.

STATUS 1 ON 2 ON

<1>

SUPPLIES INSTALLED 2 PWR REDUNDANCY

<2>

HW REV xxx FW REV x.xx.xx LOAD xxx%

PWR SUPPLY 1 SN xxxxxxxxxxxx

PWR IN 110V PWR OUT 57.1V 5.1V 3.3V