5 the main menu, 6 how to quit, 7 checking the engine data – Haltech F9A User Manual
Page 31

30
NOTE: If power is removed or the communication cable is disconnected or interfered with,
the following message will be displayed on the computer screen.
RECONNECT HALTECH
If this message appears check all connections and ensure that the communications cable is not
being interfered with. Also be sure that the Haltech F9 unit is receiving power. (i.e.. ignition
switch is turned "on".)
2.5 The Main Menu
When you select Online or Offline mode the Haltech MAIN MENU bar appears. This menu
bar allows access to submenus giving access to maps, file storage/retrieval, engine data and
options.
2.6 How to Quit
Throughout the program you can exit from any application by using the menu bars or hot
keys. Pressing
tT
in any page will prompt you to exit the program (i.e.. pressing
T
while
holding down the
t
key).If you wish to exit
<
press at the prompt.
2.7 Checking the Engine Data
The engine data option can only be used when the system is Online. This function allows all
of the engine data variables to be displayed on the screen
This is a very useful function for analysing the engine sensors. To bring up the engine data
press
tH
from any application. Otherwise it can be accessed through the menu bar by
pressing
s2
and then
(
for Engine Data.
Do not attempt start the engine if the Engine Identification has not been set up. Before
continuing check to see if all the sensors are operating correctly by viewing the engine data
page.