Where b can equal 0, 1 or no entry:
If b = 0
If b = 1
If no b is entered
Digitizer will transmit coordinate pairs whether the transducer is in
proximity or not.
Digitizer will only transmit coordinate pairs when the transducer is in
proximity.
The condition toggles.
Storing and Recalling Setup Parameters
Factory Settings
The factory settings and default operating characteristics, such as origin and prompt
character, are stored in a permanent memory location. They may be recalled by picking
Switch 6 of Bank 7. They will overwrite the current switch settings.
Baseline Settings
You may store a second set of switch settings and parameters as baseline settings by
picking Switch 8 of Bank 7 after the switches are set as desired. The tablet also stores the
origin, Increment values, command prefix, character constants, menu location and status,
the prompt character and the location of any window. These settings may be recalled by
picking Switch 7 of Bank 7. They will overwrite the current switch settings.
Current Settings
A third set of operating parameters may be stored in a non-volatile memory separate from
the baseline settings. In addition to the current soft switch settings, the tablet will store the
current origin, menu location and status, location of a window, increment values, prompt
character, command prefix and the character constants. This command may come from
the host or menu, but not the switch banks.
Host = ESC % V F CR
Menu = [SYSTEM FUNC 1] [F] [CR]