GTCO 2500 Series - Users Guide 3/3 User Manual
Page 17

2500 Series 17
If b = 0
If b = 1
If b = 2
If b = 3
LED #2 will extinguish
LED #2 will light
LED #3 will extinguish
LED #3 will light
Controlling the Tablet Displays LED’s 2500 Unique Commands
This command may control all the numbered LED’s of the tablet display. The normal
indicator function of that LED will be overridden by this command. For example, if you
have ordered LED #4 to light, it will no longer be the proximity indicator.
Host = ESC % V l a (b) CR (lowercase L)
Menu = [SYSTEM FUNC 2] [I] [a] [b] [CR]
Where a is the number, from one to eight, of the desired LED.
Where b is 0, 1 or no entry.
If b = 0
If b = 1
If no b is entered
LED will extinguish.
LED will light.
The LED will toggle.
Set Serial Communications Parameters 2500 Unique Command
This command configures the output port. The baud rate, parity, data bits, start bits, stop
bits and handshaking that were set in the soft switches can be overridden by the
command. The tablet will recognize the command whether you specify Port A, Port B or no
port. That portion of the command was included for 9100 compatibility.
Host = ESC % C (b1) b2 b3 b4 b5 (b6) CR
Menu = [COM] ([b1]) [b2] [b3] [b4] [b5] ([b6]) [CR]