1260-chand-i, Installation instructions, Ac b l – Golden Lighting 1260-3P RBZ User Manual
Page 3

7. Unscrew the Canopy loop collar(H )from the Canopy loop.
Take the canopy and pass over the Canopy loop.
approximately one half of the canopy loop exterior threads
should be exposed. Adjust until desired height is reached. *the
Canopy loop collar should fit snugly on the Canopy loop after
the canopy is installed. Remove Canopy and Canopy lock
collar.
8. Assemble the fixture and have an assistant or secure
support hold the weight of the fixture while you complete the
wiring connections.
9.Thread the fixture wires and ground wire of the assembled
fixture through the canopy loop and nipple and into the outlet
box.
For Customer Service, contact the place of purchase to arrange for replacement parts.
CONNECTING THE WIRES (Fig 2)
10. Attach the power supply wires to the fixture lead wires by
connecting BLACK to BLACK (or SMOOTH) and WHITE to
WHITE (or RIBBED).
11. Attach the GROUND wire(GREEN or COPPER) from the
Junction Box and the fixture Ground wire to the green Ground
Screw on the Mounting Bracket (D) or connect both wires
together using the correct size of wire connectors.
NOTE: Twist the wires together in the same direction you twist
the wire connector onto the wires.
12. Tuck these wire connections neatly into the Junction Box.
Fig. 2
FINISHING THE INSTALLATION
13. Raise the Canopy (G) to the ceiling. Secure in place by
tightening the Canopy Loop Collar (H) onto the Canopy Loop
(F).
14. Install the light bulbs and glass shade according to the
fixture assembly sheet.
YOUR INSTALLATION IS NOW COMPLETE.
RETURN POWER TO THE JUNCTION BOX
AND TEST THE FIXTURE.
For Chandelier Light Fixture
INSTALLATION INSTRUCTIONS
WARNING ! SHUT OFF POWER AT FUSE OR CIRCUIT BREAKER.
Fixture Name: Candace 1260-5 /-D5/-9/-3P PW/RBZ
HANGING THE FIXTURE (Fig.1)
1. Carefully remove the new fixture from the carton and the
yellow bag that holds all parts. Check that all parts are included
as shown in the illustration and parts list.
2. Shut off the power at the circuit breaker and remove old
fixture from ceiling, including the old mounting strap.
3. Thread Nipple(C) into Canopy Loop (F) until snug.
4. Thread other end of the Nipple (C) with Canopy Loop
attached into Mounting Strap (D).
5. Place Lock Washer (B) over end of Nipple (C) protruding
through Mounting Strap (D) and thread Hex Nuts (A) onto
Nipple until tight.
6. Take this mounting strap assembly and mount to ceiling
junction box with Mounting screws (E). Tighten screw securely
with screw driver.
Fig. 1
G
CHAIN
J
H
F
E
D
JUNCTION BOX
(CEILING)
A
C
B
L