The explanation of the items in this menu are given below.
Automatic transfer:

This defines the transfer mode (“1” automatic transfer, “2” manual transfer)

Transfer by:

This defines the transfer frequency base. (day, hour, minute or each record)

Transfer frequency:

This defines the period of the automatic record transfer

Last transfered record:

This index shows the serial number of the last transferred record. It is possible
to change this number. In this case the automatic transfer starts at the defined
serial number.

Destination:

This defines the destination of the record file in which the data will be saved

Frequency example: If is set to “Day” and to “1”, the automatic
transfer will start at the end of each day. However, if to “1”, the automatic transfer will be started after finishing every 2

nd

weighing.


To alter a letter menu item (via a selection table, but not a numerical menu part) use the “Space” key.
To save the changes, press the “Enter” key several times until the menu closes.

7.4.4 Manual Data Transfer (requires FT-16 Ethernet option

It can be used e.g. for data backup if weighing data have to be saved on a network drive over an Ethernet
connection. Press [F5] to transfer all not yet transferred weighing records manually. The process starts
automatically and the following menu will be displayed:

Transfer

The FT-16(D) remembers the last record number which has been transferred. If all records have been
transferred already, the message “No more record to be transferred” will be shown. Press any key to return to
the 2

nd

weighing records menu.

FT-16/FT-16D Weighbridge User Manual, Rev.1.02 June 2008