Error check calculating – Flintec FT-16D V.1.21 User Manual
Page 27
Error Check Calculating:
CSUM = 0 – (Slave_Add + Function + … + Last_data)
(STX and CSUM are neglected while calculating CSUM)
Tool for counting:
0 1 2 3 4 5 6 7 8 9 A B C D E F
Example:
@|01|10|0008|0001|02||0006|DE|
To get the check sum (here FA) you have to sum following numbers first:
01+10+00+08+00+01+02+00+06 = 22
Now you have to subtracte 22 from 00:
00 - 22 = DE
(Calculation examples: 00 – 10 = F0 ; 00 – 11 = EF)
Command
Function
(Read /
Write)
Address
register
Quantity
Address
register
Quantity
Data
register
Data Definition
Display value
03 (R)
0000
0002
--
-----
Current display value; gross or net
Transfer the replied status data (hex, 4 digits)
into binary (up to 16 digits) and compare the
binary digits with the following table.
Digit Definition
D0
Busy
1 – System Busy
D1
Data ok
1 – Data ok // 0 – Error
D2 Motion
1 – Weight is not
stable
D3
Net Mode
1 – Net mode
D4 0
D5 0
D6 0
D7 0
D8 0
D9 0
D10 0
D11 0
D12 0
NA
0 No
Errors
1
ADC out of range
2
ADC over range
3
ADC under range
4 System
fault
Status 03
(R)
0002
0001
--
-----
D13
D14
D15
Error Code;
transfer
D13, D14,
D15
(binary) to
decimal and
compare to
code
5
FT not in
weighing mode
Tare weight
03 (R)
0003
0002
--
----
Current tare weight
Gross Weight
03 (R)
0005
0002
--
----
Current gross weight
---- None
0001 Zero
0002 Tare
0003 Clear
0004 Print
0005 NA
0006 NA
0007 NA
0008 NA
Control 10
(W)
0008
0001
02
0009 NA
Examples:
The commands will be used for an indicator which instrument address is set to 1.
Reading weight data:
@010300000002FA
Reading status data:
@0103000200019F
Reading Tare data:
@010300030002F7
Taring:
@011000080001020002E2
FT-16(D) Technical Manual, Rev. 1.21 December 2008