7 alibi memory and legal metrological records, Alibi memory and legal metrological records, Alibi data connector – Flintec FT-16D V.1.21 User Manual
Page 17: ] metrological data block, ] legal metrological records
7 A
LIBI
M
EMORY AND
L
EGAL
M
ETROLOGICAL
R
ECORDS
If the alibi memory is installed and activated, the indicator keeps the latest 149 764 weighing records in this
memory. The recorded data can be viewed on the indicator’s display or exported via serial port.
To find a definite record you have to enter parameter [802]. After reaching the desired record, the recorded data
can be viewed in the display. If needed you can print this record together with the following 9 records by
pressing the
port. The
Empty fields will be printed as “------“ , corrupted records as “xxxxx” . For the records for which weighing
results cannot be given, the message “no rec” will be shown on the display.
If the alibi memory is activated, the alibi record number is also found on the print out data.
After installing the alibi board or changing the main board “Error 41” or “Error 42” will be shown on the display
after power on because the activation of the alibi memory is required.
If the calibration jumper is short circuited, you can activate the alibi board by pressing the
power on. Otherwise the alibi errors will disappear by pressing the
(Error “43” will be shown after pressing the
Alibi data connector:
The alibi data connector must be used for printing the alibi records. This connector (D-Sub, 9 pin, female) is
located inside the housing.
Alibi connector within FT-16(D)
Pin no. (D-Sub, 9-pin, male)
Definition
3 TXD
5 GND
Baud rate: 9600; 1 start bit, 8 data
bits, 1 stop bit and no parity bit
[8--] Metrological Data Block
The parameters about Metrological Registry are being entered in this section.
[80-] Legal Metrological Records
In this block edit the parameters with <
↑> key and use the
description.
[800] Counter
This counter increases automatically by 1 after starting the setup mode with enabled calibration jumper
and service password. This counter cannot be changed manually.
[801] Alibi
Memory)
0 = Disabled
1 = Enabled
[802]
Finding any record from Alibi Memory
You can call any record from the Alibi Memory by
while an alibi record is on the display, this and the 9 previous records will be printed.
[803]
Print all Alibi Memory records
All data from the Alibi Memory can be printed by pressing the
[804] Alibi
Info
You can get some basic information about the alibi memory board and the records by pressing the
• SN
: Pin code of the alibi memory card
• SA
: The alibi record start number within this indicator
• LA
: The alibi record number of the next weighing with this indicator
• CN : Calibration counter number
• CS : Check sum status
• AS : Capacity of the alibi memory
FT-16(D) Technical Manual, Rev. 1.21 December 2008