Appendix 7: parameter’s default table, Ppendix, Arameter – Flintec FT-13 User Manual
Page 54: Efault, Able

FT-13 Technical Manual, Rev. 1.40 March 2013
Page 54 of 56
A
PPENDIX
7:
P
ARAMETER
’
S
D
EFAULT
T
ABLE
Parameter
Factory defaults
0-- Interface
00- Serial Interface 1
0 Data format
2 = Printer
1 Baud rate
3 = 9600
2 Handshake
0 = Disable
3 Address
0
4 Data length and parity
0 = 8 bit, no parity
5 Checksum
1 = Enable
02- Serial Interface 2
20 Data format
0 = Disable
21 Baud rate
3 = 9600
22 Handshake
0 = Disable
23 Address
0
24 Mode
0 = RS232C
25 Data length and parity
0 = 8 bit, no parity
03- Ethernet / Profibus
30 Ethernet data format
0 = Disable
31 Ethernet address
0
32 Profibus data format
0 = 32-bit integer
33 Profibus address
0
34 CANopen data format
0 = 32-bit integer
35 CANopen address
0
36 ProfiNet data format
0 = 32-bit integer
04- Printer
41 Date + Time
0 = don‟t print
1-- Configuration
12- Filter
120 Filter
6
14- Entries
140 Date entry
dd.mm.yy
141 Time entry
hh.mm
2-- Scale Parameters
20- Set up
200 Approved
0 = No
201 Increased indication
0 = With x10 key
203 Zero with key
1 = ± %2
204 Auto Zero Tracking
1 = ± 0.1e
205 Tare
1 = With Tare Key
206 Motion detector
1 = ± 0,5e
21- Scale Build
212 Capacity (2) / d(2)
6 kg / 0.001 kg
3-- Calibration / Adjustment
30- Calibration
301 Calibration
31- Adjustment
310 Zero adjustment
311 Span adjustment
312 Span adjustment under load
Parameter
Factory defaults
5-- Filling
50-
Filling Parameters
51-
500 Filling programme
Programme 0
501 Preact correction factor
30%
502 Preact correction frequency 1
503 Preact correction limit
100%
504 Coarse feed. control delay
0.7 s
505 Fine feeding control delay
0.7 s
506 Maximum settling time
1.0 s (delay 0.0 s)
507 Jogging time
0.0 s
508 Filling time
0 = Disable
509 Maximum weight
3000
50A Start / Reset keys
0 = Disable
50b Filling Quantity control
0
50C Filling type
1
50d Fine feeding time at start
0 (=starts with coarse f.)
50E Zeroing period
250 s
50F Zeroing delay
3.0 s
510 Indication in filling process
0 (= increasing)
59- Filling Performance Test
590 Coarse feed test
591 Fine feed test
8-- Metrological Data
80- Legal Metrology
800 Calibration counter
9-- Diagnostics
90- Tests
900 Key Pad test
901 Serial interface 1 test
902 Digital input test
903 Digital output test
904 mV indication
91- Serial numbers
910 FT-13 serial no.
911 Option 1 serial no.
912 Option 2 serial no.
913 Option 3 serial no.
914 A XX.--
915 A --.YY
99- Print Parameters
990 All parameters
991 Load default parameters