beautypg.com

Software-controlled store/recall cycle, Stk17t88 – Cypress AutoStore STK17T88 User Manual

Page 9

background image

STK17T88

Document Number: 001-52040 Rev. *A

Page 9 of 22

Figure 10. Software Store/Recall Cycle:

E CONTROLLED

[13]

Software-Controlled STORE/RECALL Cycle

In the following table, the software controlled STORE and RECALL cycle parameters are listed.

[12, 13]

NO.

Symbols

Parameter

STK17T88-35

STK17T88-45

Units

Notes

E Cont

Alternate

Min

Max

Min

Max

26 t

AVAV

t

RC

STORE

/ RECALL Initiation Cycle Time

25

45

ns

13

27 t

AVEL

t

AS

Address Set-up Time

0

0

ns

28 t

ELEH

t

CW

Clock Pulse Width

20

30

ns

29 t

EHAX

Address Hold Time

1

1

ns

30 t

RECALL

RECALL

Duration

100

100

ms

26

26

27

28

29

23

30

Notes

12. The software sequence is clocked on the falling edge of E controlled READs
13. The six consecutive addresses must be read in the order listed in the Software STORE/RECALL Mode Selection Table. W must be high during all six consecutive cycles.

[+] Feedback