D.A.S. Audio Variant Series Systems Guide User Manual
Page 8
6
System installation using the ceiling support AXC-V25
M8X30 DIN965
AXC-V25
Rubber washer
M8x35 DIN 912
Grower (lock) washer
Metal washer
EN
Three different washers must be used along
the M8x35 DIN912 screws and placed in the
following
order-
grower
(lock)
washer,
metal
washer and rubber washer.
In order to hang the rest of the boxes the
captive rigging hardware and safety pins will be
used, and the procedures described on the 4.3
paragraph of this manual will be followed. The
picture below shows three
units
hanging from the ceiling.
variant 25A
Before connecting the first box to the ceiling
mount accessory the two M8x30 DIN965 screws
must be removed from the
and
replaced by two M8x35 DIN912.
variant 25A
The
units can be set up as a long
array of more than four enclosures (as explained
above) or as a small array of 2, 3 or 4 units. In the
latter
case
the
highly
resistant
grid
accessory is not necessary. Instead the
ceiling mount accessory can be used to hang a
cluster of up to four units.
First attach the ceiling mount accessory to the
ceiling or a beam. Before doing so be sure that the
load bearing capability of these elements is
enough. The
will be attached to the ceiling
by means of six nº 10 rawlplugs
and six
7 x 40
mm screws.
variant 25A
AX-V25
AXC-V25
AX-V25
variant S
uide
ystems G