EOl-11006
)
Before taking in-line reports, please note the following:
1)
When the “NON-HOLD RESET” type is selected for in-line report operations, In-line
Reset Reports (as well as Read Reports) can be taken on the Master Terminal as
long as the Satellite Terminals are in the “Signed OFF” condition (for Cashier
Signing Method) or in the outside-sale condition (for Cashier Key Method).
2)
When the “HOLD RESET” type is selected for in-line reset report operations, first
take terminal reset reports on individual Master and Satellite terminals and make the
terminals into the“HOLD” condition. Then In-line Reset Report takings are allowed
on the Master Terminal. (In-line Read Reports, however, can be taken any time on
the Master Terminal.)
3)
When In-line Reports are taken, the power of each Satellite terminal must be turned
ON but the Mode Lock and GT Lock can be in any positions.
IN-LINE REPORT COMMAND EXECUTIONS
)
The operation flow for taking In-line Reports is shown on the next page, and the table of In
line Reports is on the following pages.
The key operation for each In-line Daily Report is the same as the corresponding terminal
report available on the stand-alone ECR except for the GT Lock position. Please note that
each In-line GT Report requires a 3-digit Report Code instead of a 1 or 2-digit code of the
corresponding stand-alone terminal report (for example 108 instead of 8, 117 instead of 17,
etc.).
Conditions required on terminals for In-line Report takings:
Read Reports (Daily or GT)
Master Terminal:
Any time outside a sale
Satellite Terminals:
Any time outside a sale
Reset Reports fPailv or GT)
(Refer to “NON-HOLD RESET AND HOLD RESET" on Uie previous pages.)
Master Terminal; Any time outside a sale (for Cashier Key Method)
Signed-OFF condition (for Cashier Signing Method)
Satellite Terminals:
After its own individual Terminal Reset Reports (for HOLD
RESET type)
Any time outside a sale (for Cashier Key Method of NON
HOLD RESET type)
Signed-OFF condition (for Cashier Signing Method of NON
HOLD RESET type)
Lock Positions Required
Master Terminal:
Mode Lock: X / GT Lock RTR for read reports
Mode Lock: Z / GT Lock RTR for reset reports
Satellite Terminals:
Any positions
- 1 5 -