Read(x) and reset(z) reports – Toshiba TEC MA-230 User Manual
Page 38
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

READ(X) AND RESET(Z) REPORTS
The following table shows the key operation to take each report. The "X" and
"Z" reports have exactly the same content print if both are available, except
that:
1. The "X" reports allow to read the sales data but not clear memories,
while the "Z" reports allow to read the sales data and at the same
time all the resettable memories will be cleared when the reports have
been issued,
2. The symbol "X" is printed on the top line of an "X" report, while "Z"
is printed on a "Z" report, to indicate the type of report.
3. A reset count is printed on the bottom of a "Z" report only.
TABLE OF OPERATIONS FOR X AND Z REPORTS
REPORT NAME
KEY OPERATION
MEDIA-IN-DRAWER READ
(If a media is programmed not to
print its "In-drawer Total" on
reports, that media-in-drawer
total will not be printed in
this report.)__________________
Mode Lock: X
* [#] (or [#/NS])
PLU READ AND RESET
ZONE PLU READ
ZONE PLU RESET
ALL PLU READ
ALL PLU RESET
Mode Lock: X
Mode Lock: Z
Mode Lock: Z
>1 Start PLU Code|->[X]-- j
L»|End PLU Code I-»[PLU]
Ik
[ P L U ]
INDIVIDUAL DEPARTMENT READ
(All Department Read/Reset is
contained in the AUTO READ/RESET
reports.)_______________________
Mode Lock: X, depress the required Dept
Keys, one by one. [ST] may be used to
obtain subtota, [AT/TL] to end.
DEPARTMENT GROSS PROFIT READ
Mode Lock: X ->■ 12 [AT/TL]
HOURLY READ AND RESET
HOURLY READ
HOURLY RESET
Mode Lock: Z
> 10 [AT/TL]
CLERK READ AND RESET
INDIVIDUAL CLERK READ
INDIVIDUAL CLERK RESET
(All Clerk Read/Reset is
contained in the AUTO READ/
RESET reports.)
Mode Lock: Z
3
Set the required Clerk
Key to ON ■> 1 [AT/TL]
NOTE: INDIVIDUAL CLERK READ/RESET
reports are available only when
the "4-Clerk Key-locks" status
______ is selected in the system option,
-- To be continued --