beautypg.com

Warning, 8 save these instructions – Genie Excelerator User Manual

Page 26

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

^WARNING

TO REDUCE THE RISK OF SEVERE INJURY OR DEATH

1

READ AND FOLLOW ALL INSTRUCTIONS.

2

Never let children operate or play with the Door Controls. Keep the Remote Control away from children.

3

Always keep the moving door in sight and away from people and objects until the door is completely closed.

NO ONE SHOULD CROSS THE PATH OF THE MOVING DOOR.

4

NEVER GO UNDER A STOPPED, PARTIALLY OPEN DOOR.

5 Test Opener monthly. The door MUST reverse on contact with a 1-1/2" high object (or a 2" x 4" board laid flat)

at the center of the doorway on the floor. After adjusting either the Force or the Limit of travel, retest the Door
Opener. Failure to adjust the Opener properly may cause severe injury or death.

6

When possible use the Emergency Release only when the door is closed. Use caution when using this Release

with the door open. Weak or broken springs are capable of increasing the rate of door closure and increasing
the risk of severe injury or death.

7

KEEP GARAGE DOORS PROPERLY BALANCED. See Owner's Manual. An improperly balanced door increases the
risk of severe injury or death. Have a Genie Factory Authorized Dealer make repairs to cables, spring
assemblies, and other hardware.

8 SAVE THESE INSTRUCTIONS.

^WARNING

Use the Wall Console included with Opener. Any other wall console can cause the Opener to operate unexpectedly and

the light to stop working.

1 So'r i ■ i iED)

insor

(Green LED)

1 i ■ . .iible Problem

Solution 1

tl' "

OFF

OFF

|_ Normal operation ^

1 • Power Head not powered i

• Wiring from Power Head bad

None required

• Check breakers, fuses, plugs 1

• Check wiring for obvious shorts

OFF

ON

• Wiring to Source missing or bad

• Power has been interrupted

• Check wiring

• Remove power and reapply

2 BLINKS,

Pause

(Repeat)

, ON

• Beam not aligned

1

Beam

obstructed

• Sensor defective

• Check Source, Sensor alignment

• Check for obstruction i

• Contact Customer Service

2 BLINKS,

Pause

(Repeat)

OFF

• Wire to Sensor missing or bad

• Sensor defective

• Check wiring

• Contact Customer Service

3 BLINKS,

Pause

(Repeat)

ON

• Sensor receiving interference

• Determine source of interference

• Contact Customer Service

4 BLINKS,

Pause

(Repeat)

ON

• Source not sending pulses

• Source defective

• Contact Customer Service

• Contact Customer Service

26

FcM' Help, call l-SOOHJSHSEiiE or ¥isit %wi»i.ferilecornparif.ccirn