Setting Close Limit Switch

(Figure 34):

Check that Magnetic Carriage Assembly is disengaged.

With garage door fully closed, slide Close Limit Switch

until it is aligned with Carriage Assembly Magnet.

Tighten Set Screw.

Do Not

over-tighten.

Setting Open Limit Switch:

Manually open garage door to full open position.

Slide Open Limit Switch until it is aligned with Carriage
Assembly Magnet.

Tighten Set Screw.

Do not

over-tighten.

Re-engage Magnetic Carriage Assembly.

of

Little effort is required to turn the Force

Adjusting Knobs.

If the door stops moving while opening or
closing, adjust the Open Force or Close Force
Controls

slightly

clockwise (to

slightly

increase the force) and retry the step.

The Open Force and Close Force Controls are to

be set to the

minimum

force necessary to

ensure the door smoothly opens fully and
closes completely.

The garage door will move slowly the first
time it runs, until the Opener "learns" the
type of door.

Ensure the Magnetic Carriage Assembly is

engaged and is between the two Limit
Switches before operating the Opener.

NOTE

A

WARNING

The garage door opens rapidly, and can cause serious

injury or death.

Keep the path clear.

Position the ladder to the side of the Power Head so it is
clear of all moving parts of the Opener and the door.

Set the door Opener to use the minimum force needed
to open the door.

A

Pre-set Force Controls to midpoint between fully counter

clockwise and fully clockwise

(Figure 35).

B

Adjust the Close Limit Switch:

Press Wall Console to close garage door.

-

If door does not close completely, measure distance

from bottom of door to floor. Move Limit Switch
same amount toward door and try again.

-

If door reverses after contacting floor, move Limit

Switch toward Power Head and try again.

-

If door reverses before contacting floor, increase

Close force and try again.

-

If door fails to move, check Safe-T-Beam® System. See

Safe-T-Beam® Troubleshooting Guide on pg. 26, and
Opener System Self-diagnostic Troubleshooting
on pg.27.

Tighten Limit Switch Set Screw.

Do not over-tighten

(strip) Limit Switch Set Screw.

C

Adjust Open Limit Switch:

Press Wall Console to open garage door.

-

If door does not open completely, move Limit Switch

toward Power Head.

-

If door opens completely, but motor continues to
run, move Limit Switch toward door.

Tighten Limit Switch Set Screw.

Do not over-tighten

(strip) Limit Switch Set Screw.

Close Limit Switch

(door fully closed)

Carriage

(disengaged)

Switch

Magnet

Open

Limit

Switch

Switch

(door fully open)

Carriage

(disengaged)

Magnet

Figure 34

Setting Limit Switches

Figure 35

Making Force Adjustments