A
CAUTION
Doors made of masonite, lightweight wood, fiberglass, metal,
or other lightweight materials must be properly braced
before mounting door Opener.
For stictional doors;
A
Place Door Bracket on door center line, no lower than top
roller, and mark holes
(Figure 19).
B
Attach Door Bracket:
•
For metal doors, use 3 (1/4" -20 x 3/4") Self-Drilling
Screws (provided).
•
For wood doors, use 3 (1/4" x 2") Lag Screws or
3 (1/4"
X
11 /4") Lag Screws (not provided).
NOTE
Before installing, check length of the included Lag Screws vs.
the thickness of your garage door. For doors thinner than 2",
use 11/4" Lag Screws. Check door condition and thickness.
See page 3.
(28
(5^ or (g)
(28)
SECTIONAL DOORS ONE-PIECE DOORS
Center Line of dooL,-::;:=:gi J Center Line of door .
/. I OR
Attach no "
lower than
.1
top rollers
■'Attach
at
j
highest point j
on door
Optional Door Operator Bracket (not included)
Figure 19
Attach Door Bracket
For ontf-plecef doors:
A
Position Door Bracket on door's center line, as high as
possible or on top of door.
B
Attach Door Bracket:
•
For metal doors, use 3 (1/4" -20 x 3/4") Self-Drilling
Screws.
•
For wood doors, use 3 (1/4" x 2") Lag Screws.
A
While supporting the Power
Head,
place threaded end of Rail
Strap Bolt through Header Bracket hole
(Figure 20).
B
Attach (5/16"-18) Flange Nut to Rail Strap Bolt.
Finger-tighten until later.
FcM' Help, call
1
-
800
-
3
S
4
SEiiE or visit svswi.ferileccirnpiirif.corn