beautypg.com

Data retention characteristics, Data retention waveform switching waveforms – Cypress CY7C1019D User Manual

Page 6

background image

CY7C1019D

Document #: 38-05464 Rev. *E

Page 6 of 11

Data Retention Characteristics

(Over the Operating Range)

Parameter

Description

Conditions

Min

Max

Unit

V

DR

V

CC

for Data Retention

2.0

V

I

CCDR

Data Retention Current

V

CC

= V

DR

= 2.0V, CE > V

CC

– 0.3V,

V

IN

> V

CC

– 0.3V or V

IN

< 0.3V

3

mA

t

CDR

[3]

Chip Deselect to Data Retention Time

0

ns

t

R

[12]

Operation Recovery Time

t

RC

ns

Data Retention Waveform

Switching Waveforms

Read Cycle No. 1 (Address Transition Controlled)

[13, 14]

Read Cycle No. 2 (OE Controlled)

[14, 15]

4.5V

4.5V

t

CDR

V

DR

>

2V

DATA RETENTION MODE

t

R

CE

V

CC

PREVIOUS DATA VALID

DATA VALID

RC

t

AA

t

OHA

t

RC

ADDRESS

DATA OUT

50%

50%

DATA VALID

t

RC

t

ACE

t

DOE

t

LZOE

t

LZCE

t

PU

HIGH IMPEDANCE

t

HZOE

t

HZCE

t

PD

HIGH

ICC

ISB

IMPEDANCE

OE

CE

ADDRESS

DATA OUT

V

CC

SUPPLY

CURRENT

Notes

12. Full device operation requires linear V

CC

ramp from V

DR

to V

CC(min)

> 50

µs or stable at V

CC(min)

> 50

µs.

13. Device is continuously selected. OE, CE = V

IL

.

14. WE is HIGH for Read cycle.
15. Address valid prior to or coincident with CE transition LOW.