Quality Monitor Status Indications and Common Solutions
17
Leakage
Symptom
Probable Cause
Solution
Leak at fitting
Tubing not pushed completely
Push tube into fitting past
into fitting
O-ring seal
Defective tube
Cut damaged area from tube or
replace tube
Tubing makes too tight a bend
Run the tubing to reduce the bend
near fitting
Leak at filter
O-ring has not seated properly
Remove O-ring and inspect
housings
O-ring groove for debris. Clean
groove, lube and reseat O-ring
O-ring has nicks or scratches
Replace O-ring
Leak from air gap
Restricted drain tube
Clear restriction
in faucet
Tubing from air gap to drain is
Re-route tubing so tubing runs
routed incorrectly
vertically with no sharp bends
or loops
Leakage
Indication
Condition
Action
Green Light
System operating normally
None
Orange Light (appears
Shut-off valve is not closing
Call your Culligan
®
dealer
with green or yellow light
Yellow Light
Membrane exhausted
Replace membrane
No Monitor Lights
Light Assembly is not connected
Plug connector into phone jack
Battery voltage low
Replace battery
Battery is not connected
Connect battery