12. Place a small amount of O-ring lubricant on surface of filter housing O-ring. Install O-ring into

housing.

TO SANITIZE THE SYSTEM: Complete Steps 13-33.

TO INSTALL FILTERS: Complete Steps 20-33.

CAUTION: Wear safety glasses while performing this procedure.

CAUTION: Read “WARNINGS” information on bleach container before using con-

tents. Handle sanitizing solution carefully. Avoid contact with unprotected areas.

13. Mix sanitizing solution of 1.5 ml (1/3 teaspoon) of household bleach and 3.8 L (1 gallon) of

clean, potable water in the bucket. Mix solution well.

Note: Excessive concentrations of bleach (sodium hypochlorite) may damage plastic and rub -

ber components. Rinse all parts that contact bleach thoroughly with clean potable water.

14. Add 236 ml (one cup or 8 oz.) of sanitizing solution to each filter housing and install

them onto the manifold (do not install filters or membrane at this time). Tighten

each filter housing by hand only.

12