Note: Tighten filter housings by hand only. Do not use tools as they will over-tighten and dam -
age housings.
15. Slowly open source water supply valve.
16. Close product water faucet as soon as water begins to flow from spout.
17. Wait 5 minutes, then close source water supply valve.
18. Wait 25 minutes, then open product water faucet. Let water flow to drain until system is
drained (flow stops), then close faucet.
Note: Remove filter housings only after water flow stops.
19. Remove filter housings and dispose of water. Rinse housings/manifold thoroughly with clean,
potable water.
Note: Do not remove protective plastic bag from replacement filter and membrane cartridges.
Note: For optimum monitor performance, the monitor must be re-set and the battery replaced
each time system is sanitized. However, a technician may wait until indicator lights fail to illumi -
nate to replace battery.
20. Hold cartridge by its protective plastic bag and open protective bag to expose cartridge cap and
O-rings.
21. Install cartridges. (Refer to Figure 5 for location of each cartridge).
a. Hold cartridge by its protective plastic bag.
b. Insert cartridge into manifold turning it 1/2 turn as it enters port. Slide bag from cartridge
and discard.
c. Install filter housing (Item 30) as each cartridge is inserted. Make sure housing o-ring is
properly lubricated.
Note: Tighten filter housings by hand only. Do not use tools as they will over-tighten and dam -
age housings. Take care not to cut or pinch the O-rings.
22. Turn feed water valve slowly to open position.
23. Confirm system is producing water. Unit will be sending rinse water to drain. Check
for leaks.
Note: Monitor must be re-set each time the system is serviced to ensure accurate monitor per -
formance.
13