Note: Tighten filter housings by hand only. Do not use tools as they will over-tighten and dam -

age housings.

15. Slowly open source water supply valve.

16. Close product water faucet as soon as water begins to flow from spout.

17. Wait 5 minutes, then close source water supply valve.

18. Wait 25 minutes, then open product water faucet. Let water flow to drain until system is

drained (flow stops), then close faucet.

Note: Remove filter housings only after water flow stops.

19. Remove filter housings and dispose of water. Rinse housings/manifold thoroughly with clean,

potable water.

Note: Do not remove protective plastic bag from replacement filter and membrane cartridges.

Note: For optimum monitor performance, the monitor must be re-set and the battery replaced

each time system is sanitized. However, a technician may wait until indicator lights fail to illumi -

nate to replace battery.

20. Hold cartridge by its protective plastic bag and open protective bag to expose cartridge cap and

O-rings.

21. Install cartridges. (Refer to Figure 5 for location of each cartridge).

a. Hold cartridge by its protective plastic bag.

b. Insert cartridge into manifold turning it 1/2 turn as it enters port. Slide bag from cartridge

and discard.

c. Install filter housing (Item 30) as each cartridge is inserted. Make sure housing o-ring is

properly lubricated.

Note: Tighten filter housings by hand only. Do not use tools as they will over-tighten and dam -

age housings. Take care not to cut or pinch the O-rings.

22. Turn feed water valve slowly to open position.

23. Confirm system is producing water. Unit will be sending rinse water to drain. Check

for leaks.

Note: Monitor must be re-set each time the system is serviced to ensure accurate monitor per -

formance.