beautypg.com

Operating instructions, Before the water heater will operate, Operation – Kenmore 153.335963 User Manual

Page 24

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

Operating Instructions

This water heater is equipped with an electrically operated vent­

ing system and a standing pilot. For the burner to come on, the

water heater thermostat must call for heat. Then the system will

begin

sequencing,

each

section

proving

itself

before

gas

is

allowed to flow to the burner.

BEFORE THE WATER HEATER WILL OPERATE:

1.

The

control

system

must

be

connected

to

a

110/120

volt

power supply. The control system has an overall rating of 2

amps.

The

water

heater

must

be

securely

and

adequately

grounded

in

accordance

with

local

codes

and

with

the

latest

edition of the National Electrical Code ANSI/NFPA 70.

2.

The

ON/OFF

toggle

switch,

located

on

the

control

box

above

the

thermostat

must

be

in

the

“ON”

position

for

the

electrical

control

system

to

operate

allowing

the

gas

portion

to operate (ignite burner).

3. The pilot must be lit. See Lighting instructions on page 23

of

this

manual

or

located

adjacent

to the

thermostat on

the

water heater.

4.

The

gas

control

knob

located

on

the

thermostat

must

be

turned to the “ON” position for the gas to be able to flow.

5.

The venting manual reset switch must be in the closed posi­

tion.

See

“Venting

Manual

Reset

Switch”

in

the

“For

Your

Information Section”.

6

.

There

is

a

non-resettable

hi-limit

switch

in

the

thermostat,

which must be good (closed) for the thermostat to be oper­

ated,

See

“High

Temperature

Shut

Off

System”

in

the

“For

Your Information Section”,

OPERATION

When the thermostat calls for heat, gas is allowed to flow to a

(Normally

open)

pressure

switch

closing

it.

An

electrical

circuit

is

then

made

to

the

blower,

turning

it

on.

The

indicator

light

located on the control box will come on. When the blower has

achieved

sufficient

venting,

the.air

pressure

switch

will

close

and

the indicator light will go off. A 120 volt circuit will be com­

pleted

through

the

venting

manual

reset

switch

and

on

to

the

120

volt

gas

valve

located

just

below

the

thermostat.

The

120

volt gas valve will open allowing gas to 0ow to the burner. The

standing pilot will establish a main burner flame.

GAS CONTROL

24

This manual is related to the following products: