Venting Through Roof - Clearances

#

0" clearance for 3" (or optional

2

") PVC, ABS, or CPVC Schedule

40 piping from combustible surfaces.

The Power Vent outlet terminal shall terminate at least 18" above

the roof surface. Figure 5.

#

The location selection must provide clearances for servicing and

proper operation of the water heater. Figure 4,

The venting system must be installed in a manner which allows

inspection of the installation of the venting pipes and joints as

well as periodic inspection after installation as required by ANSI

Standards.

Installation Instructions (cont'd)

11