beautypg.com

Installation instructions (cont’d) – Kenmore 153.335963 User Manual

Page 18

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

2.

Horizontal runs require a minimum

'/"

rise per foot.

Installation Instructions (cont’d)

VENTING

SYSTEM

EXAMPLE

INSTALLATIONS

FOR ALL MODELS

The

vent

piping

cannot

under

any

circumstances

be

run

down­

hill.

The vent piping can be instiled as follows;

1. No more than

3

elbows

can

be used.

3.

The

total

vertical

and

horizontal

run

cannot

exceed

35'

for

3"

vent

piping

(20'

maximum

if

2"

vent

piping

is

used

on

40,000

BTU/Hr.

models)

with

a

maximum

of

three 90° elbows.

18

This manual is related to the following products: