Installation Instructions (cont’d)
Installation Checklist
BEFORE LIGHTING THE PILOT:
Check the gas lines for leaks.
a. Use a soapy water solution. DO NOT test for gas leaks
using a match or open flame,
h. Brush the soapy water solution on all gas pipes, joints and
fittings,
c. Check for bubbling soap. This means you have a leak.
Turn “OFF” gas and make the necessary repairs.
d. Rechcck for leaks.
e. Rinse off soapy solution and wipe dry.
Is
the
new
temperature-pressure
relief
valve
properly
installed
and
piped
to
an
adequate
drain?
See
“Temperature-Pressure
Relief Valve” section.
Are
the
cold
and
hot
water
lines
connected
to
the
water
heater
correctly?
See
“Water
Piping”
instructions
in
the
“Installing the New Water Heater” section.
Is the water heater completely filled with water? See “Filling”
instructions
in
the
“Instating
the
New
Water
Heater”
sec
tion.
Will
a
water
leak
damage
anything?
See
the
“Locating
the
New Water Heater” section.
Is
there
proper
clearance
between
the
water
heater
and
any
thing that might catch fire? See the “Locating the New water
Heater” section.
Do
you
have
adequate
ventilation
so
that
the
water
heater
will
operate
properly?
See
“Combustion
Air
and
Ventilation”
in the “Locating the New Water Heater” section.
Is the draft hood vent piping properly secured? See “Venting”
instructions
in
the
“Installing
the
New
Water
Heater”
sec
tion.
Is
there
proper
clearance
between
the
vent
pipe
and
anything
that
might
catch
on
fire?
See
“Venting”
instructions
in
the
“Installing the New Water Heater” section.
Is the vent pipe properly sloped and does the vent terminate
outdoors?
See
“Venting”
instructions
in
the
“Installing
the
New Water Heater” section,
.
Do you need to call your gas company to check the gas pipe
and its hookup?
VENT PIPE TO
OUTDOORS
COLD
TEMPERATURE-
PRESSURE RELIEF
VALVE
DISCHARGE PIPE
(Do not cap or plug)
TEE
--------------
DRIP LEG---------
(Sediment trap)
PIPE CAP---------------- VVfe
"AUTfflIATIC STORAGE WATER
HEATER" SUITABLE FOR WATER
(POTABLE) HEATING ONLY
MCDEL NUMBER CAfitMiTY
EQUIPWD ANSZSV10
FOR MfUr RECOVERY SEf
UALNLMBER
OAS BnjkHH QM.AW.
MAXIMUM HYOnOSTATIC QAS PRESSURE IN W.C
V№*nNG mOBUHC feUUI MMMftMWSCU» tâtUtfOUO
150
P.a.1 W.C W.C. W-0
MODEL RATING PLATE
23