Installation Instructions (cont’d)
USE WITHOUT POWER CORD (cont’d)
3. A standard
V"
conduit opening has been made in the water
heater junction box for the conduit connection.
4. Use wire nuts and connect the power supply wiring to the
wires inside the water heater’s junction box,
5. The water heater must be electrically “grounded” by the
installer, A green ground screw has been provided on the
water
heater’s
junction
box.
Connect
ground
wire
to
this
location.
For
complete
grounding
details
and
all
allowable
exceptions,
refer
to
local
codes
or
in
the
absence
of
local
codes, with the latest edition of the National Electrical Code,
ANSI/NFPA 70.
6
. Replace the wiring junction cover using the screw
provided.
WIRING DIAGRAM
Venting
AWARNING
To insure proper venting of this gas-fired water heater, the cor
rect vent pipe diameter must be utilized. Any additions of
other gas appliances on vent with this water heater will
adversely affect the operation of the water heater.
The combustion and ventilation air flow must not be obstructed.
AWARNING
The vent pipe from the water heater must slope upward 1/4
Inch per linear foot.
,
All vent gases must be completely vented to the outdoors of the
structure (dwelling).
AWARNING
The water heater with draft hood installed must be properly
vented to a chimney which terminates outdoors. Never oper
ate the water heater unless it is vented to the outdoors and has
adequate air supply to avoid risks of improper operation, explo
sion or asphyxiation.
AWARNING
Obstructed or deteriorated vent systems may present a serious
health risk or asphyxiation.