INSTALLATION INSTRUCTIONS
KEY DIMENSIONS AND SPECIFICATIONS
Description
Dryer (Gas and Electric)
Electrical Requirements
Please refer to the rating label.
Gas Requirements* Natural:
6-8
inches WC
Gas Requirements* Propane:
10-13 inches WC
Dimensions
27" (W) X 28 15d6" (D) X 45" (H), 50 1/4" (D With door open)
68
.
6
cm (W) X 73.4 cm (D) X 114.1cm (H), 127.5 cm (D With door open)
Net Weight
Electric : 147 lb. (66.7kg) / Gas : 150.5 lb. (68.3kg)
Drying Capacity
lEC 7.3 cu. ft.
m
Z
O
r
(7)
*Gas Models only.
LOCATION REOUIREMENTS
IMPORTANT:
Read all installation instructions completely before
installing and operating your dryer!
It is important that you review this entire manual before
installing and using your dryer. It contains detailed
instructions concerning electrical connections, gas con
nections and exhaust requirements.
CHOOSE THE PROPER LOCATION
• Store and install the dryer where it will not be exposed
to temperatures below freezing or exposed to outdoor
weather conditions.
• Choose a location with a solid, level floor.
• If the dryer is being installed in a garage, place the
dryer at least 18 inches (45.7cm) above the floor.
• Properly ground the dryer to conform with all governing
codes and ordinances.
• To reduce the risk of electric shock, do not install
the dryer in damp or wet locations.
IMPORTANT: If you are installing your dryer in a
manufactured or mobile home, please refer to the
section
Special Electrical Requirem ents for M obile or
M anufactured H om es on page 12.
CLEARANCES
• Most installations require a minimum 5-1/2 in.
(14 cm) clearance behind the dryer for
the exhaust ducting.
• Allow minimum clearances of at least 1 in.
(2.5 cm) on the sides and back to minimize
vibration and noise.
• Allowing additional clearance for installation
and servicing is recommended.
• Be sure to allow for wall, door, or floor moldings
that may increase the required clearances.
• Allow at least 21 inches (53.3 cm) in front of the
dryer to open the door.
21 1/4"
(54 cm)
n
4"_^|
(10
cm)
28 15/16"
(73.4 cm)
4"
1'
(10 cm) (2.5 cm)
1"
50 1/4"
(127.5 cm)
27"
(68.6 cm)
(2.5 cm)
Closet Door Clearance Requirements
Additional Instructions for closet Installations:
• The closet door must allow for sufficient airflow. Refer to
the diagram to the left for minimum vent opening or door
clearance requirements. A louvered door is also
acceptable.