CUSTOMER RESPONSIBILITIES
Thank You for
purchasing a Kenmore water heater. Properly
installed and maintained, it should give you years of trouble free
service. If you should decide that you want the new water heater
professionally installed by Sears call 1-800-4-MY-HOIVIE®. They
will arrange for prompt, quality installation by Sears authorized
contractors.
Abbreviations Found In This Instruction Manual:
CSA - Canadian Standards Association
ANSI - American National Standards Institute
NFPA - National Fire Protection Association
ASME - American Society of Mechanical Engineers
GAMA - Gas Appliance Manufacturers Association
This
gas-fired
water
heater
is
design
certified
by
CSA
INTERNATIONAL
under
American
National
Standard/CSA
Standard for Gas Water Heaters ANSI Z21.10.1 • CSA 4.1
(current edition).
Read the “Safety Precautions” section, page 3 of this manual
first and then the entire manual carefully. If you don't follow
the safety rules, the water heater will not operate properly. It
could
cause
DEATH,
SERIOUS
BODILY
INJURY
AND/OR
PROPERTY DAMAGE.
This manual contains instructions for the installation, operation,
and maintenance of the gas-fired water heater. It also contains
warnings through out the manual that you must read and be
aware of. All warnings and all instructions are essential to the
proper operation of the water heater and your safety. Since
we cannot put everything on the first few pages,
READ THE
ENTIRE
MANUAL
BEFORE
ATTEMPTING
TO
INSTALL
OR
OPERATE THE WATER HEATER.
The installation must conform with these instructions and the
local code authority having jurisdiction. In the absence of
local codes, installations shall comply with the following:
The National Fuel Gas Code ANSI Z223.1/NFPA 54. This
publication
is
available
from
the
Canadian
Standards
Association, 8501 East Pleasant Valley Rd, Cleveland Ohio
44131,
or
The
National
Fire
Protection
Association,
1 Batterymarch Park, Quincy, MA 02269.
If after reading this manual you have any questions or do not
understand any portion of the instructions, call the Sears
Service Center.
Carefully plan the place where you are going to put the water
heater.
Correct
combustion,
vent
action,
and
vent
pipe
installation
are
very
important
in
preventing
death
from
possible
carbon
monoxide
poisoning
and
fires.
See
figure 1.
Examine the location to ensure the water heater complies
with the
Facts to Consider About the Location section in this
manual.
For California installation this water heater must be braced,
anchored, or strapped to avoid falling or moving during an
earthquake.
See
instructions
for
correct
installation
procedures.
Instructions
may
be
obtained
from
your
local
dealer, wholesaler, public utilities or California Office of the
State Architect, 400 P Street, Sacramento, CA 95814.
Massachusetts Oode requires this water heater to be installed
in
accordance
with
Massachusetts
248-CMR
2.00:
State
Plumbing Code and 248-CMR 5.00.
Complies
with
SCAQMD
rule
#1121
and
districts
having
equivalent NOx requirements.
PRODUCT SPECIFICATIONS
MODEL NUMBER
TANK
CAPACITY
IN GALS (LTRS)
TYPE
OF
GAS
INPUT
RATE
(Btu/hrj
RECOVERY
RATE
GALS.
PER
HOUR
@90°F
RISE
MINIMUM
VENT PIPE
INCHES
(mm)
DIAMETER
INCHES
(mm)
DIMENSIONS
IN INCHES
(mm)
HEIGHT TO
JACKET TOP
153.334430
40(151)
NATURAL
40,000
46.9
3” (76) or 4" (102)
20 1/2” (521)
55 1/2" (1,410)
153.334530
50(189)
NATURAL
40,000
45.8
3" (76) or 4" (102)
22” (558)
56 1/2" (1,435)