Troubleshooting guide, Troubleshooting guide -29 – Kenmore 153.33443 User Manual
Page 28
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
TROUBLESHOOTING GUIDE
These guidelines should be used by a qualified service agent. Call Sears Service at 1-800-4-MY-HOME® (1-800-469-4663)
for assistance. Inform the associate that this is a “Flammable Vapor ignition Resistant" Product.
Problem
LED Status
Cause
Solution
GAS
VALVE
OFF
Electronic control module off or pilot
assembly off.
Check for power to heater.
Check wiring harness for proper connection.
Check for line voltage at harness connectors.
1 flash *
Electronic control module is powered
and pilot lit.
Normal operation. No action required.
2 flashes *
Thermopile voltage low.
Inspect thermopile connection to gas control
valve.
Inspect flame coverage on thermopile.
Check inlet gas pressure.
Run open circuit thermopile output test and
change thermopile if output is low.
Replace pilot assembly.
3 flashes *
Gas control valve or tank sensor
failure.
Restart gas control valve.
If main burner turns on after restart, replace
tank sensor.
If main burner does not turn on after restart,
replace gas control valve.
4 flashes *
Gas control valve overheat failure
(pilot off or burner off).
Replace gas control valve assembly and
electric control module.
5 flashes *
Lower tank sensor failure (pilot on
and burner off).
Verify tank sensor is connected to electric
control module.
Verify tank sensor is connected to the heater
tank.
Run tank sensor calibration check.
Replace tank sensor and electric control
module.
6 flashes *
Upper tank sensor failure (pilot on
and burner off).
Verify tank sensor is connected to electric
control module.
Verify tank sensor is connected to the heater
tank.
Run tank sensor calibration check.
Replace tank sensor and electric control
module.
7 flashes *
Electric control module failure (pilot
on or off and burner off).
Replace electric control module.
8 flashes *
Gas control valve failure (pilot off and
burner off).
Replace gas control valve assembly and
electronic control module.
6 second solid light
followed by 4 flashes *
Pilot stays lit only when control knob
is depressed in PILOT position.
Overheat failure. Replace gas control valve
assembly and electronic module.
6 second solid light
followed by 7 flashes *
Pilot stays lit only when control knob
is depressed in PILOT position.
Electronic control module failure. Replace
module.
6 second solid light
followed by 8 flashes *
Pilot stays lit only when control knob
is depressed in PILOT position.
Gas control valve failure. Replace gas control
valve assembly and electronic control
module.
6 second solid light with
combinations of 4 + 7
flashes *
Pilot stays lit only when control knob
is depressed in PILOT position.
Overheat failure and electronic control
module failure. Replace gas control valve
assembly and electronic module.
6 second solid light with
combinations of 4+ 8
flashes *
Pilot stays lit only when control knob
is depressed in PILOT position.
Overheat failure and gas control valve failure.
Replace gas control valve assembly and
electric module.
6 second solid light with
combinations of 7 + 8
flashes *
Pilot stays lit only when control knob
is depressed in PILOT position.
Electric control module failure and gas
control valve failure. Replace gas control
valve assembly and electronic module.
6 second solid light with
combinations of 4 + 7 + 8
flashes *
Pilot stays lit only when control knob
is depressed in PILOT position.
Overheat failure, electronic control module
failure, and gas control valve failure. Replace
gas control valve assembly and electronic
module.
Continuous solid light
System shutdown/safety interlock.
Wait until light goes out to restart gas control
valve.
Flashes are approximately 1/10 second in duration with approximately three seconds between groups of flashes.
28