OPERATING INSTRUCTIONS
FOR YOUR
SAFETY READ BEFORE
LIGHTING
WARNING
Ilf you do not follow these instructions exactly,
fire or explosion may result causing property damage, personal
injury or loss of life.__________________________________
BEFORE LIGHTING: ENTIRE SYSTEM MUST
BE FILLED
WITH WATER AND AIR PURGED FROM ALL LINES
A. This appliance
has a
pilot which is lit by a piezo- *lf you cannot reach your gas supplier, call the fire
ill1iSlr№fiSSpi^e%n8tryWt
the pilot by
hand.
C.Use only your hand to push in or turn the gas control
B. BEFORE LIGHTING smell all around the appliance knob. Never use tools. If the knob will not push in or
area for gas. Be
sure
to smell next to the
floor
turn
by hand, don't try to repair it, call a qualified
because some
gas is
heavier
than air and will
service technician. Force or attempted repair
may
settle on the floor.
result in a fire or explosion.
WHAT TO DO IF YOU SMELL GAS
p.
not use this appliance if any part has been under
water. Immediately contact a
qualified installer
or
service agency to replace a flooded water heater.
Do not attempt to
repair the unit! It
must
be replaced!
• Do not
try
to
light
any appliance.
•Do not touch any
electric
switch; do
not
use any
phone In your building.
►Immediately call
your
gas
supplier
from
a
neighbor's
phone. Follow
the
gas
supplier's instructions.
LIGHTING INSTRUCTIONS
-GAS CONTROL
KNOB
PIEZO'-
IGNITOR
STATUS-
L.E.D.
GAS CONTROL
FIGURE '
FIGURE X:'
PLOT
"OFF' POSITION
PILOT
"PILOT" POSITION
-CONTROL KNOB
PLOT
"ON* POSITION
PILOT
FIGURE 'D'
1
.
STOP! Read the safety
information
above on this label.
2. Turn gas control knob fully counterclockwise
to
"OFF".
SEE FIGURE 'A'.
3.
Remove the outer burner door located below
the
gas control.
4. Wait five (5) minutes to dear out any gas. If you
then
smell
gas.^ffl^STOP! Follow
"B"
in the
^felyinlbrmationfB^ above on this label.
If
youdontsmell
gas,^S^ go to
next
step.
5. This
unit
is equipped with a push button pilot ignitor,
which
is used to light the pilot. Locate
the
ignitor
on the gas control.
6 Turn gas control knob
clockwise
C l o
"PILOT" . SEE FIGURE 'B'.
7.
The pilot is located on the right side of the burner.
It
can be located by looking through the glass
view
port
while
pressing the piezo
ignitor
button
several times.
Look for a
spark at
the pilot
location,
Figure 'D'.
8. Once the pilot has
been
found, push the gas
control
knob
all
the way in (toward
the water
heater.)
Immediatley
press
the
piezo ignitor button rapidly (4)
or(5)
limes.
If the
pilot will not light, repeated steps (2) through (8).
9.
Coninue to hotel the ^Kcoritrd knob hfer about
(30) seconds after the pilot is lit until the status L.E.D,
is
flashing (one flash every
three
seconds is
normal.)
Release the gas conW knob and the pilot should
remain
fL
If
it goes out, repeat
steps
(2) through (8).
It may take several minutes for air to clear the lines
before
the
pilot will light.
• if the pilot will not stay lit after several
tries,
turn the gas conW knob counierdockwiae T)
to "OFF'and call
your service technician or
gas
supplier. SEE FIGURE 'A'.
10.
Once the pilot flame is established replace
the
outer burner door.
11-
At
arm's
length
away, turn gas control
knob clockwise
C
to desired temperature setting.
SEE FIGURE 'C.
DANGER:
Hotter water increases
the risk
of scald injury.
Consult
the instruction
manual before changing temperature.
A
TO
TURN
OFF GAS TO
APPLIANCE______
I . T u r n c o n i r o l / t h e r m o s t a t k n o b f u l l y c o u n t e r c l o c k w i s e t o " O F F '
SEE
F I G U R E
' A ' .
18