Operational Conditions (Continued)

Leakage Checkpoints

FIGURE 27.

AWARNING

Read and understand instruction
manual

and

safety

messages

before

installing,

operating

or

servicing this water heater.

Failure to follow instructions and

safety messages could result in
death or serious injury.

Instruction Manual must remain

with water heater.

Read this manual first. Then before checking the water heater

make sure the gas supply has been turned “OFF”, and never

turn the gas “ON” before the tank Is completely full of water.

Never use this water heater unless it is completely filled with

water. To prevent damage to the tank, the tank must be filled

with water. Water must flow from the hot water faucet before

turning “ON” gas to the water heater, see Figure 27.

A. Water at the draft hood is water vapor which has condensed

out of the combustion products. This is caused by a problem

in the vent. Contact the gas utility.

B.

^Condensation may be seen on pipes in humid weather or

pipe connections may be leaking.

C. *The anode rod fitting may be leaking.

D.

Small

amounts

of

water

from

temperature-pressure

relief

valve may be due to thermal expansion or high water pressure

in your area.

E. *The temperature-pressure relief valve may be leaking at the

tank fitting.

F. Water from a drain valve may be due to the valve being slightly

opened.

G. *The drain valve may be leaking at the tank fitting.

H.

Combustion

products

contain

water

vapor

which

can

condense on the cooler surfaces of the tank. Droplets form

and drip onto the burner or run on the floor. This is common

at the time of start-up after installation and when Incoming

water is cold.

I.

Water in the water heater bottom or on the floor may be from

condensation,

loose

connections,

or

the

relief

valve,

DC NCT replace the water heater until a full inspection of all

possible water sources is made and necessary corrective

steps taken.

Leakage from other appliances, water lines, or ground seepage

should also be checked.

* To check where threaded portion enters tank, insert cotton

swab between jacket opening and fitting. If cotton is wet,

follow “Draining” instructions in the

Periodic Maintenance

section and then remove fitting. Put pipe dope or teflon

tape on the threads and replace. Then follow

Fiiling the

Water Heater instructions in the Installing the New Water

Heater section.