beautypg.com

Cleveland Range Steam Cooker and Rethermalization Unit 22CET3A User Manual

Page 9

background image

5

c. Place the KleanShield¥ into the steamer with

pipe extension towards the back and facing
down. Set the KleanShield¥ in place over the

corresponding pipe extending out of the bottom of
the steamer reservoir. See Figure 2-3.

d. The KleanShield¥ is installed properly when the

pipe from the KleanShield¥ is fitted into the

corresponding pipe in the bottom of the steamer
and its legs are flush against the bottom of the
steamer. See Figure 2-6.

4. Inspecting The Cooking Compartment

a. Before turning ON the power switch/lever to the

SteamChef¥ 3, the entire inside of the steamer

must be thoroughly cleaned.

b. All food debris should be wiped clean and the

drain openings and the water level sensors shall
be inspected and cleaned of any residue or
debris (See Figure 2-4).

c. The door gasket assembly, KleanShield¥, fan

guard and slide racks should be inspected for
proper installation and cleanliness. See Chapter
2, Section A, Part 3 for proper installation of the
KleanShield¥.

x

To properly install the fan guard, hold the fan
guard so that the large ends of the keyholes
are towards the bottom of the steamer. Place
all four openings over the mounts located on
the rear wall of the steamer and pull it down
so that the narrow ends of the slots are pulled
tight over the mounts. See Figure 2-5.

d. Make sure that the KleanShield¥ drain is clear. See Figure 2-6.
e. It is also recommended that a small amount of water (about a quart) be poured through the

KleanShield¥ drain. Check that water flows out the drain.

FAN

GUARD

KLEANSHIELD¥

Figure 2-6 Inspecting Compartment

Interior Accessories

REMOVABLE

PAN RACKS

Figure 2-4 Inspecting

Compartment drains

OVERFLOW

DRAIN

WATER
LEVEL
SENSOR
ASSEMBLY

RESERVOIR

DRAIN

OPENING

Figure 2-5 Fan Guard Shown in

Installed Position

FAN GUARD

SHOWN PULLED

DOWN TO LOCK IT

IN PLACE

LARGE END OF

KEYHOLE AT

BOTTOM

Figure 2-3 KleanShield¥

Installation

FIT UP OF

KLEANSHIELD¥

PIPE