Cleveland Range Steam Cooker and Rethermalization Unit 22CET3A User Manual
Page 12
8
1. “SureCook” Indicator Light
This Amber light is lit whenever the cooking
compartment has not yet reached the optimum cooking
temperature. Note: when in the timed mode the timer
will not count down as long as this light is ON.
2. TIMER
This dial timer sets the operating time from 0 to 60
minutes. Turn the dial clockwise until it points to the
required number of minutes. When it reaches 0, a
buzzer sounds for 3 seconds.
3. POWER ON Indicator Light
When the Green indicator light is ON, power is ON to
the operating controls.
4. RESET Indicator Light
When this light is lit, it indicates that the high limit
circuit of the steamer has opened. This light will remain
ON, and a buzzer will sound until power to the unit has
been reset. See High Limit Reset in Chapter 2, Section
A, Part 7 for additional details.
5. TIMED/MANUAL Switch
The TIMED/MANUAL switch selects the manual or
timed operating mode.
x Pressing the MANUAL end of the switch selects the
manual mode.
x Pressing the TIMED end of the switch selects the
timed mode.
6. Serial Number/Model Number Display
2. ON/OFF Control Panel
a. Cooking Operations – ON/OFF Control Panel
For safe, efficient operation of the steamer, the operator must, at a minimum, comply with all
cautions, warnings and instructions in the detailed operating procedures and be familiar with the
control panel shown in Figure 2-9. The operator must be familiar with all the operating features
explained in this manual before attempting to operate the steamer.
Figure 2-8 Dial Timer Control Panel
1
2
6
3
5
4