5. Positioning and Leveling the Steamer
Move the steamer into position. Using a level, adjust the adjustable legs of the unit or the Cleveland
Range stand as applicable until the unit is level.
6. Installation of the KleanShield¥
a. Never operate a SteamChef¥ Steamer without a properly installed KleanShield¥.
b. Note the KleanShield¥ must be installed before the side pan racks.
c. Place the KleanShield¥ into the steamer with pipe
extension towards the back and facing down. Set
the KleanShield¥ in place over the corresponding
pipe extending out of the bottom of the steamer
reservoir. See Figure 4-9.
d. The KleanShield¥ is installed properly when the
pipe from the KleanShield¥ is fitted into the
corresponding pipe in the bottom of the steamer
and its legs are flush against the bottom of the
steamer. See Figure 2-6 in Chapter 2 showing an
installed KleanShield¥.
7. Installing the Fan Guard
To properly install the Fan Guard, hold the fan guard
so that the large ends of the keyholes are towards the
bottom of the steamer. Place all four openings over the
mounts located on the rear wall of the steamer and pull
it down so that the narrow ends of the slots are pulled
tight over the mounts. See Figure 4-10.
8. Install Slide Racks and Rear Vent
a. Refer to Figure 4-11. Each rack has four loops:
two at the top and two at the bottom. Hold the
slide rack so the ends of the hanger loops are
towards the cavity wall, as shown in the figure.
b. Slide one rack into the compartment with loops
toward one side.
c. Hook the loops over the top and bottom pins.
d. Repeat steps a. through c. for the other racks.
e. Using pipe sealant (not provided), install the drain tee into the rear of the steamer using the close
nipple provided, as shown in Figure 4-12. (Note: For Steamers installed on a Cleveland Range
Model ES222824S Stacking Stand refer to the instructions found in Section B, Part 3 of this
Chapter, for proper vent installation).
WARNING
INJURY AND EQUIPMENT DAMAGE could result from improper
lifting. A Model Number 22CET3 weighs approximately 250
pounds. Use enough workers with experience lifting heavy
equipment to place the steamer on the supporting surface.
Figure 4-9 KleanShield¥
Installation
Figure 4-10 Fan Guard Shown
in Installed Position
FAN GUARD
SHOWN PULLED
DOWN TO LOCK IT
IN PLACE
LARGE END OF
KEYHOLE AT
BOTTOM