Operating your thermostat – Braeburn 1220NC User Manual
Page 8
7
User
Factory Setting
No.
Options
Default
Options
Comments
1
1st stage
0.5
0.5, 1.0
Select a 1st stage temperature
differential
or 2.0
differential of .5˚, 1˚ or 2˚F (.2˚, .5˚
or 1˚C)
2
2nd stage
2.0
1.0, 2.0,
Select a 2nd stage temperature
differential
3.0, 4.0,
differential of 1˚, 2˚, 3˚, 4˚, 5˚ or 6˚F
(1220NC Only)
5.0 or 6.0 (.5˚, 1˚, 1.5˚, 2˚, 2.5˚ or 3˚C)
Table of User Options
Detailed Explanation of User Options:
Temperature Differential
(User Option 1 and 2)
The differential setting is the temperature control range that your thermostat
will provide. The smaller the setting, the tighter your range of temperature
control and comfort will be. The 2nd stage differential is only for systems
with a second stage of heating (auxiliary heat).
6
Operating Your Thermostat
Setting the System Control Mode
The System Control has several modes of operation that can be selected by
moving the SYSTEM switch to the appropriate position.
COOL Only your cooling system will operate
OFF Heating and cooling systems are off.
HEAT Only your heating system will operate.
Additional Switch Position (Model 1220NC Only):
EMER Operates a backup heat source (Emergency Heat) for heat pump
systems only.
NOTE: If your model 1220NC was configured for a
conventional system (CONV) then you will not have
the EMER (emergency heat) option and “NO EMER
SET” will flash in the display if EMER is selected
with the system switch.
Setting the Fan Control Mode
The Fan Control has 2 modes of operation – AUTO
and ON. The mode can be selected by moving the
FAN switch to the appropriate position.
AUTO The system fan will run only when your
heating or cooling system is running.
ON
The system fan stays on.