Page 3: Additional operation features

background image

4

PROGRAMMING

USER SETTINGS

4

Setting Temperature Differentials

Setting First Stage Differential

NOTE:

The first and second stage differential settings are the same for both the

heating and cooling systems.

NOTE:

If you do not wish to change the second stage differential setting, you can press

the and buttons at the same time twice to proceed to the Residual Cooling fan

setting–see 4.3.

The default settings for the first and second stage differentials and residual cooling fan delay

settings are compatible with most systems and applications. This is normally set at time of

installation and usually does not require any modification under normal operating conditions.

If you feel that the first or second stage of your system is turning on too often, or you wish to

change the fan delay settings, follow the instructions below.

2. Press the or button to set the first stage

differential to your desired setting of .5˚, 1˚, or 2˚ F (0.25˚, .5˚, or 1˚ C).

The default setting is .5˚ F (0.25˚ C). The room temperature must change .5˚ F (0.25˚ C) from

the setpoint temperature before the thermostat will initiate the system in heating or cooling.

1. In normal operating mode, press and hold the

and button at the same time for 4 seconds.

LCD display will show "

SET D1 X˚", where "X"

equals the ˚F / ˚C differential setting. This is the

current first stage differential setting.

Setting Residual Cooling Fan Feature

Setting Second Stage Differential

The default setting is 2˚ F (1.0˚ C). This means that

the room temperature must change 2˚ F (1.0˚ C) in

addition to the first stage differential setting before the

thermostat will initiate the second stage of the system

in heating or cooling.
3. Press the and buttons at the same time again

and the LCD display will show "

SET D2 X˚", where "X"

equals the ˚F / ˚C differential setting. This is the current second stage differential setting.
4. Press the or button to set the second stage differential to your desired setting of 2˚, 3˚,

4˚, 5˚, or 6˚ F (1.0˚, 1.5˚, 2.0˚, 2.5˚, or 3.0˚ C).

4.2

cont.

1. Press the and buttons at the same time again and the LCD display will show

"

SET FAN XX", where "XX" equals the fan delay time in seconds during the cooling

mode of operation.

2. Press the or button to set the residual cooling fan delay to your desired setting
of 0 (disabled), 30, 60, or 90 seconds.

The default setting is 60 seconds. During the

COOL

mode of normal operation the fan will stay on for 60

seconds after the cooling system has satisfied the

setpoint temperature and has turned off the

compressor. This allows the system to provide

higher efficiency during cooling operation.

3. Press the and buttons at the same time again to set the Recirculating Fan Cycle
or wait 5 seconds and the thermostat will automatically return to normal operating mode.

4.3

5.2

Changing Set Temperature

1. Press and hold or button for 3 seconds. The

entire display will flash once and the

SET TEMP

indicator will be flashing. Release the or

button and press the or button again as

desired to adjust the set temperature.

2. The display will return to normal operating mode

after 5 seconds.

3. The TEMP indicator will be showing in the display

indicating that the current temperature shown in the

display is the room temperature.

5

5.1

Review Set Temperature

1. Press and hold the or button. The current

setpoint temperature will be displayed in the place

of the current room temperature, and the indicator

SET TEMP will be displayed.

2. The display will return to normal operating mode

when the or button is released. Continuing

to hold the or button for 3 seconds or longer

will allow the user to change the current setpoint

temperature (See Changing Set Temperature).

ADDITIONAL

OPERATION FEATURES

5

PROGRAMMING

USER SETTINGS

cont.

4

4.4

Setting the Recirculating Fan Cycle

(Also see section 5.3)

The default is 120 minutes.
1. The display will show "SET OC XXX", where XXX is

the maximum interval of time (in minutes) that the

fan will remain off if the Recirculating Fan Mode

is selected.
2. Press the or button to change the Recirculating

Fan off cycle (120, 60, or 40 minutes).
3. Press both the and buttons at the same time again to return to the normal

operating mode, or wait 5 seconds for the thermostat to return to the normal

mode automatically.

NOTE:

To erase all user program setting, gently press the RESET button using a paper clip

or a small pencil tip. This will return all thermostat settings to their default values.

NOTE:

Select either Cool or Heat with the system

switch to view or change separate cooling or

heating setpoints.