5

Daily Maintenance

WARNING!

T

HE

E

STEEM

MUST

BE

INSPECTED

AND

SERVICED

ANNUALLY

,

PREFERABLY

AT

THE

START

OF

THE

HEATING

SEASON

,

BY

A

QUALI

-

FIED

SERVICE

TECHNICIAN

. I

N

ADDITION

,

THE

MAINTENANCE

AND

CARE

OF

THE

BOILER

AS

EXPLAINED

IN

THIS

MANUAL

MUST

BE

PER

-

FORMED

TO

ASSURE

MAXIMUM

EFFICIENCY

AND

RELIABILITY

. F

AILURE

TO

SERVICE

AND

MAINTAIN

THE

E

STEEM

AND

THE

SYSTEM

COMPONENTS

COULD

RESULT

IN

EQUIPMENT

FAILURE

,

CAUSING

POSSIBLE

PERSONAL

IN

-

JURY

,

DEATH

OR

PROPERTY

DAMAGE

.

Daily Maintenance

Check the Surrounding Area

WARNING!

T

O

REDUCE

POTENTIAL

OF

SEVERE

PERSONAL

INJURY

,

DEATH

OR

SUBSTANTIAL

PROPERTY

DAMAGE

,

ELIMINATE

ALL

THE

MATERIALS

LIST

-

ED

ON

PAGE

2

FROM

THE

AREA

SURROUND

-

ING

THE

UNIT

AND

FROM

THE

VICINITY

OF

THE

COMBUSTION

AIR

INLET

.

I

F

CONTAMINANTS

HAVE

BEEN

NEAR

THE

UNIT

OR

AIR

INLET

FOR

AN

EXTENDED

PERIOD

,

CALL

A

QUALIFIED

SERVICE

TECHNICIAN

TO

INSPECT

THE

UNIT

FOR

POSSIBLE

ACID

COR

-

ROSION

DAMAGE

.

I

F

PRODUCTS

CANNOT

BE

REMOVED

,

IMME

-

DIATELY

CALL

A

QUALIFIED

SERVICE

TECHNI

-

CIAN

TO

RE

-

PIPE

THE

AIR

INLET

PIPING

AND

RELOCATE

IT

AWAY

FROM

THE

CONTAMINAT

-

ED

AREAS

.

Combustible / flammable materials - Do not
store combustible materials, gasoline or
other flammable vapors or liquids near the
unit. Remove immediately if found.

Air contaminates - Products containing chlo-
rine or fluorine, if allowed to contaminate the
combustion air, will cause acidic condensate
within the unit. This will cause significant
damage to the unit. Read the list of potential

materials listed on page 2 of this manual.
If any of these products are in the room
from which the unit takes its combustion air,
they must be removed immediately or the
combustion air intake must be relocated to
another area.

Check Combustion Air Inlets

• Verify that ventilation air openings to the

mechanical room are open and unob-
structed.

• Verify that the unit’s vent termination

and combustion air intake are clean and
free of obstructions. Remove any debris
on the air intake or flue exhaust open-
ings. If removing the debris does not
allow the unit to operate correctly, con-
tact your qualified service technician to
inspect the unit and the vent / combus-
tion air system.

Check Temperature Display and Pressure
Gauge

• Ensure the pressure reading on the

pressure gauge does not exceed 25
psig. Higher pressure readings may indi-
cate a problem with the expansion tank.

• Ensure the temperature on the display

panel does not exceed 194

ºF. Higher

temperature readings may indicate a
problem with the operating thermostat
controls.

• Contact a qualified service technician if

problem persists.

Chapter 3 Maintenance Procedures

GF-125U