Chapter 3 maintenance procedures, Warning, 5daily maintenance – AERCO Esteem Users Guide User Manual
Page 8: Daily maintenance, Gf-125u

5
Daily Maintenance
WARNING!
T
HE
E
STEEM
MUST
BE
INSPECTED
AND
SERVICED
ANNUALLY
,
PREFERABLY
AT
THE
START
OF
THE
HEATING
SEASON
,
BY
A
QUALI
-
FIED
SERVICE
TECHNICIAN
. I
N
ADDITION
,
THE
MAINTENANCE
AND
CARE
OF
THE
BOILER
AS
EXPLAINED
IN
THIS
MANUAL
MUST
BE
PER
-
FORMED
TO
ASSURE
MAXIMUM
EFFICIENCY
AND
RELIABILITY
. F
AILURE
TO
SERVICE
AND
MAINTAIN
THE
E
STEEM
AND
THE
SYSTEM
COMPONENTS
COULD
RESULT
IN
EQUIPMENT
FAILURE
,
CAUSING
POSSIBLE
PERSONAL
IN
-
JURY
,
DEATH
OR
PROPERTY
DAMAGE
.
Daily Maintenance
Check the Surrounding Area
WARNING!
T
O
REDUCE
POTENTIAL
OF
SEVERE
PERSONAL
INJURY
,
DEATH
OR
SUBSTANTIAL
PROPERTY
DAMAGE
,
ELIMINATE
ALL
THE
MATERIALS
LIST
-
ED
ON
PAGE
2
FROM
THE
AREA
SURROUND
-
ING
THE
UNIT
AND
FROM
THE
VICINITY
OF
THE
COMBUSTION
AIR
INLET
.
I
F
CONTAMINANTS
HAVE
BEEN
NEAR
THE
UNIT
OR
AIR
INLET
FOR
AN
EXTENDED
PERIOD
,
CALL
A
QUALIFIED
SERVICE
TECHNICIAN
TO
INSPECT
THE
UNIT
FOR
POSSIBLE
ACID
COR
-
ROSION
DAMAGE
.
I
F
PRODUCTS
CANNOT
BE
REMOVED
,
IMME
-
DIATELY
CALL
A
QUALIFIED
SERVICE
TECHNI
-
CIAN
TO
RE
-
PIPE
THE
AIR
INLET
PIPING
AND
RELOCATE
IT
AWAY
FROM
THE
CONTAMINAT
-
ED
AREAS
.
Combustible / flammable materials - Do not
store combustible materials, gasoline or
other flammable vapors or liquids near the
unit. Remove immediately if found.
Air contaminates - Products containing chlo-
rine or fluorine, if allowed to contaminate the
combustion air, will cause acidic condensate
within the unit. This will cause significant
damage to the unit. Read the list of potential
materials listed on page 2 of this manual.
If any of these products are in the room
from which the unit takes its combustion air,
they must be removed immediately or the
combustion air intake must be relocated to
another area.
Check Combustion Air Inlets
• Verify that ventilation air openings to the
mechanical room are open and unob-
structed.
• Verify that the unit’s vent termination
and combustion air intake are clean and
free of obstructions. Remove any debris
on the air intake or flue exhaust open-
ings. If removing the debris does not
allow the unit to operate correctly, con-
tact your qualified service technician to
inspect the unit and the vent / combus-
tion air system.
Check Temperature Display and Pressure
Gauge
• Ensure the pressure reading on the
pressure gauge does not exceed 25
psig. Higher pressure readings may indi-
cate a problem with the expansion tank.
• Ensure the temperature on the display
panel does not exceed 194
ºF. Higher
temperature readings may indicate a
problem with the operating thermostat
controls.
• Contact a qualified service technician if
problem persists.
Chapter 3 Maintenance Procedures
GF-125U