19.4 Message Flow

The following graph illustrates the message flow for the calculation and validation of banking
keys.

19.4.1 Authorizing an Outgoing Telex via the Host

The process of authorizing an outgoing telex via the host goes as follows:

A host application posts a TOM message to an MQ Server queue serviced by TC/LINK-MQ.
The message contains banking key information, and is sent to a telex number. The Key
System is specified as an additional AUTH recipient.

TC/LINK-MQ fetches the message from the MQ Server.

TC/LINK-MQ makes the telex recipient inactive and posts the message to TCOSS.

As the AUTH recipient had an MQ address, it is fetched by another instance of TC/LINK-MQ
and posted to a queue on another MQ Server.

The All-for-one application fetches the message from the queue and calculates the key.

It creates a special TOM notification, containing the calculated key, a status, the TCOSS
message id and modified message text, and posts this notification to a queue on the MQ
server.

TC/LINK-MQ retrieves the notification from the queue.

If the notification status signals success, TC/LINK-MQ authorizes the original message on
TCOSS: the AUTH recipient is set inactive, and the telex recipient is set active instead.