Tc/link-wm, 5 how to configure network interface card teaming, How to configure network interface card teaming – Kofax Communication Server 9.1.1 User Manual
Page 82
Environment Guide
Version 3.00.04
82
© Copyright Kofax, Inc. All information is subject to change without notice.
Since one ScanJet 5 has a scanning speed of 900pages/hour, a single TC/LINK-SJ can serve at least four
scanners in parallel (parallel operation provided by HP ScanJet daemon)!
Tested with Model 2xx.
TC/LINK-WM:
KCS to TC/Link-WM 500messages/hour/GSM channel
Tested with Model 2xx.
7.5 How to Configure Network Interface Card Teaming
Network interface card (NIC) teaming is the process of grouping together several physical NICs into one
single logical NIC
The goal of the NIC teaming services is to provide fault tolerance across a team of two or more ports on a
TCOSS server.
By NIC teaming more than one physical NIC to a logical NIC, high availability of a TCOSS server is
maximized. Even if one NIC (or cables) fails, the network connection does not cease and continues to
operate on other NICs.
7.5.1
NIC Teaming with Intel Advanced Networking Services (ANS)
If a computer has at least one Intel NIC, the NIC teaming can be configured with Intel ANS. For download
The example in this chapter can help you configuring NIC teaming with Intel.
OS: Windows Server 2008 R2
Hardware (NICs):
BroadCom NetXtreme 57xx Gigabit Controller
Intel® PRO/100 S Dual/Port Server Adapter
The original state of network connections without NIC teaming:
In the Properties of the Intel NIC, go to the Teaming tab and select
“Team this adapter with other adapters”.