Block write command number 53: send tare value, Block write command number 53: send tare value -18 – Hardy HI 2151/30WC Single-Scale Controller User Manual
Page 38

HI 2151 SERIES WEIGHT CONTROLLERS REMOTE I/O OPTION
5-18
Relay 2 = Net
Word 2, bits 0 - 7 = 1110 0101 = E5 (hex)
Relay 3 = Rate-of-Change Word 2, bits 8 - 15 = 0000 0110 = 06 (hex)
Relay 4 = Peak
Relay 5 = Totalizer
Relay 6 = Gross
Relay 7 = Gross
Relay 8 = Gross
Block Write
Command Number
53: Send Tare Value
TABLE 5-20: BLOCK WRITE COMMAND NUMBER 53: SEND TARE VALUE
BLOCK WRITE COMMAND NUMBER 53:Send Tare Value
START
WORD DEFINITIONS:
#WORDS
WORD
Command number: A value of 53 (decimal)
bit 0
1
bit 1
0
bit 2
1
bit 3
0
bit 4
1
bit 5
1
bit 6
0
bit 7
0
bit 8 -15
Reserved for future use
1
0
Tare Value
2
1
TOTAL NUMBER OF WORDS
3