Chapter 5 - block transfers – Hardy HI 2151/30WC Single-Scale Controller User Manual
Page 35

Chapter 5 - Block Transfers
5-15
Block Write
Command Number
51: Activate Scale
Functions
TABLE 5-16: BLOCK WRITE COMMAND NUMBER 51: ACTIVATE SCALE FUNCTIONS
BLOCK WRITE COMMAND NUMBER 51: Activate Scale Functions
START
WORD DEFINITIONS:
#WORDS
WORD
Command number: A value of 51 (decimal)
bit 0
1
bit 1
1
bit 2
0
bit 3
0
bit 4
1
bit 5
1
bit 6
0
bit 7
0
Remote Functions Byte
bit 8
Acquire TARE (Set tare value = current gross weight)*
bit 9
Initiates print on standard RS232 or optional BCD port*
bit 10
Add current Net weight to Total*
!
bit 11
Clear Peak Hold register*
!
bit 12
Clear Totalizer Accumulation*
!
bit 13
Zero the instrument*
bit 14
Enable Zero Tracking (Blind Unit Only)
bit 15
Reserved for future use
*Note: The bit must be toggled to activate this function
!Note: Only active if the instrument is ordered with this option
1
0
TOTAL NUMBER OF WORDS
1