HI 2151 SERIES WEIGHT CONTROLLERS REMOTE I/O OPTION
5-8
TABLE 5-8: BLOCK READ COMMAND NUMBER 5: CALIBRATION PARAMETERS
Block Read
Command Number
6: Configuration of
Rate-of-Change
TABLE 5-9: BLOCK READ COMMAND NUMBER 6: CONFIGURATION OF RATE-OF-CHANGE
Motion Tolerance: A sixteen bit value representing the low 16 bits of the 20 bit internal weighing
range
1
4
Zero Tolerance: A sixteen bit value representing the low 16 bits of the 20 bit internal weighing range
1
5
Number of readings averaged: A value from 1 to 200
Note: Number of averages will temporarily read 200 if the instrument was in the CAL menu while
this block read occurred.
1
6
Span weight value or C2
®
, Second Generation reference point value‘‘
2
7
Scale Capacity (Full limit of scale): A 20 bit number in proper integer format
2
9
Mid-point Linearity Calibration Value: A 20 bit number in proper integer format
2
11
TOTAL NUMBER OF WORDS
13
BLOCK READ COMMAND NUMBER 5:Calibration Parameters
START
WORD DEFINITIONS:
#WORDS
WORD
BLOCK READ COMMAND NUMBER 6: Configuration of Rate-of-Change
START
WORD DEFINITIONS:
#WORDS
WORD
Command number: A value of 6 (decimal)
bit 0
0
bit 1
1
bit 2
1
bit 3
0
bit 4
0
bit 5
0
bit 6
0
bit 7
0
bits 8 - 15
Reserved for future use
1
0
Displayed Rate-of-Change time units: A value of 0 to 2 (0=sec, 1=min, 2=hr)
1
1
Rate-of-Change timebase evaluation period in seconds
0 = 1 second
4 = 5 seconds
8 = 15 seconds
12 = 240 seconds
1 = 2 seconds
5 = 6 seconds
9 = 30 seconds
13 = 450 seconds
2 = 3 seconds
6 = 10 seconds
10 = 60 seconds
14 = 900 seconds
3 = 4 seconds
7 = 12 seconds
11 = 120 seconds
15 = 1800 seconds
1
2
TOTAL NUMBER OF WORDS
3